摘要
借助化学分析、XRD,SEM及EDS等测试手段,对断裂失效的某发电厂冷凝器用锡黄铜管进行了分析。结果表明,断裂失效的原因主要是应力腐蚀和腐蚀疲劳。并根据断裂机理,提出了预防措施。
The fracture failure of Sn-brass pipe steam condenser used in power plant is analyzed by chemical analysia, XRD analysis techniques, Scanning Electrical Microscopy (SEM) and Energy Dispersive Spectrum (EDS). The resuits show that stress corrosion and corrosion fatigue are the main causes for the fracture failure. According to the analysis, some significant precautionary measures are suggested.
出处
《湖南电力》
2006年第2期19-21,共3页
Hunan Electric Power
关键词
冷凝器
断裂失效
应力腐蚀
腐蚀疲劳
steam condenser, fracture failure, stress corrosion, corrosion fatigue