期刊文献+

反渗透前不锈钢换热器失效的原因及其防护 被引量:2

FAILURE ANALYSIS OF STAINLESS STEEL HEAT EXCHANGERS IN A REVERSE OSMOSIS SYSTEM
在线阅读 下载PDF
导出
摘要 嘉兴发电厂二期工程化学补给水系统两套板框式316不锈钢加热器在短时间内相继损坏失效,在对换热器运行条件、失效宏观特征、腐蚀产物特征和材料化学成分的分析后,得出了应力腐蚀破裂的结论,并提出了相应的防范措施。 After a short period of service, two 316 stainless steel heat exchangers of the chemical feedwater system in a power plant were corroded. Through analyzing the operating conditions, crack characters, corrosion products and chemical composition of the material, it was concluded that the failure was caused by stress corrosion cracking (SCC). Some prevention measures were presented.
出处 《腐蚀与防护》 CAS 北大核心 2006年第4期212-214,共3页 Corrosion & Protection
关键词 不锈钢 换热器 氯离子 应力腐蚀破裂 Stainless steel Heat exchanger Chlorion Stress corrosion cracking
  • 相关文献

参考文献2

二级参考文献6

  • 1郑文龙.钢的环境敏感断裂[M].化学工业出版社,1989.180.
  • 2杨武.金属的局部腐蚀[M].化学工业出版社,1994..
  • 3吴玖 等.双相不锈钢[M].北京:冶金工业出版社,2000..
  • 4-.设备腐蚀与防护[M].西北工业大学出版社,..
  • 5上海市食品工业公司.味精生产技术知识[M].-,..
  • 6张振邦.耐蚀材料.大连:大连理工大学出版社,1993.