摘要
本文采用浙江省尘肺诊断考核资料,将75名专业人员的个体尘肺诊断结果与省尘肺诊断鉴定组群体诊断结果进行比较,结果各期尘肺诊断总准确率为71.31%,其中Ⅲ期最高达100.00%,Ⅱ ̄+最低为55.56%。密集度判定以不够1级准确率最高,为72.22%,1级和2级分别为68.27%和56.03%,3级最低为43.94%。类圆形小阴影判定准确率高于不规则形,前者为75.95%,后者为31.58%。
The diagnostic results for pneumoconiosis made by 75 professionals in Zhejiang Province and the Provincial Diagnosis Group respectively was compared in the paper,The results showed that the average coincidence rate between then was 71.3%,the highest among these coincidence rates was that of category H,reached 100%,the lowest was that of categoryⅡ+,only 55.56%.In the judge of shadow density,the coincidence rate for grade l,2 and 3was 68.27%,56.03%and 43.90%respectively and the coincidence rate for the judge of round shadows was 75.9%,much higher than that of the irregulor shadows,31.58%.
出处
《中国工业医学杂志》
CAS
1996年第2期72-74,共3页
Chinese Journal of Industrial Medicine
关键词
尘肺
诊断
X线诊断
pneumoconiosis,X-ray diagonsis,individual difference