摘要 为探讨催化铁内解的反应机理,在印染厂以调节池废水为研究对象进行了试验研究。试验结果表明,对于碱性印染废水,催化铁反应器的停留时间应不小于5.0h,采用厌氧运行方式对色度去除和提高可生化性更为有利,经后继生化处理后,出水有机物和色度去除率分别为75%、81.5%,出水pH呈下降趋势。 To investigate the effect of catalyzed iron inner electrolysis for treating dyeing and printing wastewater ,and enquire into the mechanism of this process, the wastewater of adjusting tank was tested by catalyzed iron inner electrolysis. The results showed that the HRT of reactor should be more than 5.0h when inflow was alkaline; anaerobic way of running was advantageous to removal of chroma and increasing biodegradation, and the efficiancies of removal of COD and chroma were respectively 75% and 81.5% after biological treatment, meanwhile pH lowered step by step in whole process.
出处 《水处理技术》 CAS CSCD 北大核心 2006年第4期56-58,62,共4页 Technology of Water Treatment
基金 国家高新技术研究发展计划(863)项目(2002AA601270) 山东省环保局资助项目(2004030288)
关键词 催化铁内电解法 印染废水 停留时间 运行方式 catalyzed iron inner electrolysis method printing and dyeing wastewater HRT running way
  • 相关文献

参考文献5

  • 1徐文英,周荣丰,高廷耀.催化铁内电解法处理难降解有机废水[J].上海环境科学,2003,22(6):402-405. 被引量:53
  • 2Gilham R W,O'Hannesin S F.Enhanced degradation of halogenated aliphatics by zero-valent iron[J].Ground Water,1994,32(6):958-967.
  • 3Schlimm C,Heitz E.Development of a wastewater treatment proc ess:reductive dehalogenation of chlorinated hydrocarbons by metals[J].Environmental Progress,1996,15 (1):38-47.
  • 4徐文英,周荣丰,高廷耀,马鲁铭,刘剑.混合化工废水处理工艺的研究[J].给水排水,2003,29(5):52-55. 被引量:36
  • 5李亚新译,R E斯皮思著.工业废水的厌氧生物技术[M].北京:中国建筑工业出版社,2001.