摘要 目的建立高效液相色谱-蒸发光散射检测法测定脂肪乳注射液中磷脂酰胆碱(PC)含量。方法采用Lichrospher 100Diol柱(4.6mm×250mm,5μm),以正庚烷-异丙醇(86:114)为流动相A,正庚烷-异丙醇-水(31:62:12)为流动相B,进行梯度洗脱。流速为1.0mL·min^-1,柱温为40℃;蒸发器温度80℃,空气,喷气流速为2.0L·min^-1,结果磷脂酰胆碱的线性范围为0.134~0.938g·L^-1,r=0.9982(n=7),PC加样回收率为98.9%,RSD为0.3%(n=9)。结论本法操作简便快速、重复性好、灵敏度高、准确、专属性高。 OBJECTIVE To develop a HPLC-ELSD method for the de.termination of phnsphatidyl choline(PC) content in the medium and long chain fat emulsion injection. METHODS The separation was performed on a Lichrospher 100 Diol cnhann (4.6 mm×250 mm, 5μm) with n-heptane-iso-propanol(86: 114) as mobile phase A and n-heptane-iso-propanol-water(31:62:12) as mobile phase B using linear gradient elution. The flow rate was set at 1.0 mL·min^-1. Column temperature was 40℃, inlet heater was 80℃. The air flow rate was 2.0 L·min^-1.RESULTS The linear range for the content of PC was 0.134~0.938 g·L^-1,r=0.9982(n=7). The recovery of PC was 98.9% and its RSD was 0.3% ( n = 9). CONCLUSION The method is simple, rapid, reproducible, good sensitive, accurate and is suitable for the determination of phosphatidyl choline.
作者 徐伟东 聂亮
出处 《中国药学杂志》 CAS CSCD 北大核心 2006年第4期306-307,共2页 Chinese Pharmaceutical Journal
关键词 脂肪乳注射液 磷脂酰胆碱 高效液相色谱-蒸发光散射检测法 fat emulsion injection phosphatidyl choline HPLC-ELSD
  • 相关文献

参考文献4

  • 1LUOHF TANGZR.The clinical study and stability of homemade fat emulsion injection[J].广州医学院学报,1994,22(04):107-108.
  • 2LIW SHAOYY HUANGGD.Study on the preparation of high—puritylecithin[J].山西食品工业,2001,02:5-7.
  • 3Drug specifications promulgated by the ministry of public health,Part2,Vol.6(卫生部药品标准二部第六册)[S].1998:117.
  • 4Import drug registration standard JX20000256(进口药品注册标准JX20000256)[S].2001:4-9.

同被引文献14

引证文献3

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部