摘要 In order to investigate the feasibility regarding micro-satellite posture steering by laser micro-propulsion, a laser torsion pendulum has been set up so as to get first-hand basic physical and mechanical parameters on laser micro-propulsion. The instrumentation consists of the optical, mechanical, and electrical sub-systems. The optical system includes the m,-fin beam optics, the measuring optics, and the observation optics. The mechanical system includes the gyration apparatus, transverse translation stage, vertical translator, focal lenses translator, calibration pendulum translator, and vacuum chamber. For the electrical system a computer is used to control stepping motors to drive the above moving apparatuses. With this instrument the calibration experiment and laser ablation experiment have been carried out. The experimental results demonstrate that the instrument has the capacity to measure impulse down to 10^-8 N.s with an error of about 10.4%, which can satisfy the requirement of micro-impulse lneasurelnent. In order to investigate the feasibility regarding micro-satellite posture steering by laser micro-propulsion, a laser torsion pendulum has been set up so as to get first-hand basic physical and mechanical parameters on laser micro-propulsion. The instrumentation consists of the optical, mechanical, and electrical sub-systems. The optical system includes the m,-fin beam optics, the measuring optics, and the observation optics. The mechanical system includes the gyration apparatus, transverse translation stage, vertical translator, focal lenses translator, calibration pendulum translator, and vacuum chamber. For the electrical system a computer is used to control stepping motors to drive the above moving apparatuses. With this instrument the calibration experiment and laser ablation experiment have been carried out. The experimental results demonstrate that the instrument has the capacity to measure impulse down to 10^-8 N.s with an error of about 10.4%, which can satisfy the requirement of micro-impulse lneasurelnent.
作者 李静 唐志平
出处 《Chinese Optics Letters》 SCIE EI CAS CSCD 2005年第2期76-79,共4页 中国光学快报(英文版)
关键词 CALIBRATION Mechanical drives Optical systems PENDULUMS PROPULSION SATELLITES Stepping motors Calibration Mechanical drives Optical systems Pendulums Propulsion Satellites Stepping motors
  • 相关文献

同被引文献26

引证文献4

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部