期刊文献+

巩膜环扎外加压术对角膜前表面屈光性状的影响 被引量:3

Anterior Corneal Topographic Changes after Scleral Buckling Surgery
暂未订购
导出
摘要 目的探讨巩膜环扎外加压术后角膜前表面屈光性状改变的规律。方法采用前瞻性自身对照研究,对30例(30眼)因孔源性视网膜脱离接受巩膜环扎外加压术的患者在术前ld、术后1周、1个月和3个月,分别用OrbscanⅡ角膜地形图仪检测术眼的角膜前表面屈光度、散光度、散光轴向和不规则散光度P并分析不同手术因素对角膜前表面屈光性状的影响。结果巩膜环扎外加压术引起角膜前表面周边部术后1周屈光度显著减小(P<0.01);中央部散光度显著增加;散光轴向向加压块中点轴向偏移,术后1周中央部与术前比较差异具有显著性(P<0.05);不规则散光度变化差异无显著性。手术中环扎带的长度和加压块的宽度与各屈光参数的变化有显著相关性。结论巩膜环扎外加压术后的角膜前表面屈光改变以短期为主。医生在手术操作中应尽量减小对角膜形状的改变,以保证术后的视觉恢复。 Objective To investigate corneal refractive changes after scleral buckling surgery. Methods In a prospective self-controlled clinical study, we investigated the changes of refractive power, astigmatic power, astigmatic axis, and irregular astigmatic power of anterior corneal surface following scleral buckling surgery for retinal detachment in 30 patients (30 eyes). The corneal shapes were detected by Orbscan Ⅱ topography at 1 day before surgery, and 1 week, 1 month, and 3 months after surgery. The effects of some surgical factors on the anterior corneal refractive changes were analyzed. Results After surgery, refractive power on corneal anterior surface decreased significantly in peripheral zone at 1 week (P 〈 power did not change significantly. There was a significant correlation between the encircling length/the buckle width and the refractive changes of corneal anterior surface. Conclusion Refractive changes of corneal anterior surface following scleral buckling surgery was mainly temporary. Changes in the shape of corneal should be minimizd to ensure a favorable postoperative visual acuity.
出处 《中国医学科学院学报》 CAS CSCD 北大核心 2005年第6期734-738,共5页 Acta Academiae Medicinae Sinicae
基金 浙江省教育厅科研基金(2004G20479)~~
关键词 角膜地形图 巩膜环扎外加压术 孔源性视网膜脱离 屈光改变 corneal topography scleral buckling retinal detachment refractive changes
  • 相关文献

参考文献10

  • 1Sinha R,Sharma N,Verma L,et al.Corneal topographic changes following retinal surgery.BMC Ophthalmol,2004,4(1):10
  • 2Hayashi H,Hayashi K,Nakao F,et al.Corneal shape changes after scleral buckling surgery.Ophthalmology,1997,104(5):831-837
  • 3Okada Y,Nakamura S,Kubo E,et al.Analysis of changes in corneal shape and refraction following scleral buckling surgery.Jpn J Ophthalmol,2000,44(2):132-138
  • 4Weinberger D,Lichter H,Loya N,et al.Corneal topographic changes after retinal and vitreous surgery.Ophthalmology,1999,106(8):1521-1524
  • 5Citirik M,Batman C,Acaroglu G,et al.Analysis of changes in corneal shape and bulbus geometry after retinal detachment surgery.Int Ophthalmol,2004,25(1):43-51
  • 6Ornek K,Yalcindag FN,Kanpolat A,et al.Corneal topographic changes after retinal detachment surgery.Cornea,2002,21(8):803-806
  • 7Tomidokoro A,Oshika T,Kojima T.Corneal astigmatism after scleral buckling surgery assessed by Fourier analysis of videokeratography data.Cornea,1998,17(5):517-521
  • 8Wang HZ,Chen MT,Chang .CH,et al.The changes of ocular axial length and corneal curvatures after scleral buckling for retinal detachment.Gaoxiong Yi Xue Ke Xue Za Zhi,1994,10(2):77-83
  • 9Muller-Albach KA,Dick B,Pavlovic S.Changes in bulbus geometry after conventional detachment surgery.Study using video keratoscop.Ophthalmologe,1995,92(5):677-680
  • 10Domniz YY,Cahana M,Avni I.Corneal surface changes after pars plana vitrectomy and scleral buckling surgery.J Cataract Refract Surg,2001,27(6):868-872

同被引文献31

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部