摘要
对1080管线进行了现场取样,通过试验研究了强度、韧性等材料性能的变化,结果表明材料的塑性和韧性指标下降明显。
Piping 1080 of benzol hydro - refining unit was sampled. The material properties including tensile strength, toughness of this component had been degraded by long- term operation at elevated temperature. Experiment results indicate that the piping material degradation occurs during the operation, resulting in decreases in plasticity and toughness.
出处
《压力容器》
北大核心
2006年第1期33-39,共7页
Pressure Vessel Technology
关键词
高温临氢
材料性能
损伤分析
high temperature hydrogen exposure
material properties
damage analysis