摘要
某低碳非调质钢的连铸方坯表面纵裂伴有凹陷,凹陷表面是柱状晶,未发现激冷层。认为是由于结晶器冷却制度不当,钢坯在结晶器内产生表面凹陷,造成气隙过大,致使激冷层产生了温度回升,导致激冷层发生再结晶而形成柱状晶。
Split crack and sag appeared on the surface of continuous casting biltet of a certain non-quendned and tempered low-carbon steel. The surface of the sag has columnar grain and there is no chilled layer. Because of the impropriety of mould cooling,the surface sag on the hitler in the mould, and oversize gap appear. The temperature increases again, which causes the recryslallization of chilled layer and the appearance of columnar grain.
出处
《物理测试》
CAS
2006年第1期59-62,共4页
Physics Examination and Testing
关键词
裂纹
激冷层
连铸坯
crack, chilled layer
continuous billet