结合实际检测工作,根据JJG 1059-1999《测量不确定度评定与表示》计量技术规范的要求,对工作用玻璃液体温度计示值修正值测量结果进行了不确定度分析与计算。其结果对工作用玻璃液体温度计的检定与校准工作具有一定的参考价值。
Combining with practical measuring work, and according to JJG 1059-1999 Evaluation and Expression of Uncertainty, the uncertainty of measured correction value of glass liquid thermometer readings was analyzed and calculated, The results provided reference ot the verification and calibration of glass liquid thermometer.