沙角B电厂两台锅炉的再热器出口直立管段先后发生爆管,爆管位置和发生爆管的运行小时数均十分相近,本文对此作了详细分析,并提出对策。
Tube failure happened at vertical outlet sections in two boilers in Shajiao 'B' power plant, one after another,with the similarity in the failure place and operation time. An allalysis on those tube failures is presented in this paper,and countermeasures are proposed.