期刊文献+

水听器式便携超声参数测量系统的研制 被引量:1

A Portable Acoustic Output Parameter Measurement System Using Hydrophone for the Medical Ultrasonic Diagnostic Equipment
在线阅读 下载PDF
导出
摘要 目的:开发了一套测量声输出参数的系统,为进一步研制适用于军事计量巡检工作的便携式仪器奠定基础。方法:采用水听器作为换能器,采集超声信号在空间声场焦平面上一点的声压波形。通过对声压波形的参数进行数值运算,得到所关心的超声声输出参数。结果:能够在误差允许的范围内测量出主要的声输出参数。结论:该方法切实可行,得到的数据可重复性好。 Objective: In order to suit the need of military itinerant inspection, an acoustic output measurement system, which is the basement for the manufacture of a portable instrument, is dcvclopped. Method: A hydrophonc is used as energy converting equipment to collect waves of acoustic pressure in the field of ultrasonic. Though some calculations, a series of acoustic output parameters are achieved. Results: The main acoustic output parameters can be measured in the range of permitted errors. Conclusions: This method is feasible and data can be well repeated.
出处 《中国医学物理学杂志》 CSCD 2006年第1期49-51,55,共4页 Chinese Journal of Medical Physics
基金 2001年全军军事计量"十五"科研攻关课题(GL.301)
关键词 医用超声诊断设备 水听器 声输出参数 测量 medical ultrasonic diagnostic equipment hydrophone acoustic output parameters measurement
  • 相关文献

参考文献8

  • 1International Electrotechnical Commission. IEC 1102 (61102)[S]:Measurementand characterisation of ultrasonic fields using hydrophones in the frequency range 0.5 MHz to 15 MHz. Geneva:IEC, 1991.
  • 2International Eleetroteehnieal Commission. IEC 1220 (61220)[S]:Ultrasonics -Fields -Guidance for the measurement and characterization of ultrasonic fields generated by medical ultrasonic equipment sing hydrophones in the frequency range 0.5 MHz to 15 MHz.Geneva: IEC, 1993.
  • 3周龙甫,罗二平,申广浩,吴晓明.医用超声功率计的研究及其应用[J].中国医学物理学杂志,2005,22(1):409-411. 被引量:4
  • 4K. Beissner. Intercomparison of acoustic output measurements of a diagnostic ultrasound device[J]. Ultrasound in Med. & Biol., Vol.25, No. 4, pp. 629-636, 1999.
  • 5Richter KP, Lange P. Ultrasound pressure and intensity measurements with pvdf hydrophones[J]. Seripta Med 1988,61:99-105.
  • 6寿文德,钱德初.医用超声测量用PVDF探针形高频微型水听器的研制[J].应用声学,1996,15(5):24-26. 被引量:4
  • 7童诗白.模拟电子技术基础(第2版)[M].北京:高等教育出版社,1999.339-472.
  • 8何光渝 雷群.Delphi常用数值算法集[M].科学出版社,.128-131.

二级参考文献16

共引文献6

同被引文献11

  • 1ZHONG Hui WAN Mingxi JIANG Yifeng WANG Supin.Ultrasound imaging and evaluation of lesion induced by High Intensity Focused Ultrasound[J].Chinese Journal of Acoustics,2006,25(2):104-115. 被引量:1
  • 2李秀平.体元模型法三维超声成像及其应用[J].安阳师范学院学报,2006(2):65-66. 被引量:1
  • 3罗琛,王晓春,李穗,李川,王延群.AD9271在全数字超声成像系统中的应用[J].电子产品世界,2007,14(12):86-86. 被引量:1
  • 4A Trucco,F Bertora.Improving harmonic imaging by a novelbeamforming process for ultrasound medical scanners. IEEE International Conference on Image Processing . 2005
  • 5Hendrik J Vos,Martijn E Frijlink,Erik Droog,et al.Transducerfor Harmonic Intravascular ultrasound imaging. IEEETransactions on Ultrasonics,ferroelectrics,and frequency control . 2006
  • 6A Trucco,F Bertora.Improving harmonic imaging by a novelbeamforming process for ultrasound medical scanners. IEEE International Conference on Image Processing . 2005
  • 7Hendrik J Vos,Martijn E.Frijlink,Erik Droog,et al.Transducerfor Harmonic Intravascular ultrasound imaging. IEEETransactions on Ultrasonics,ferroelectrics,and frequencycontrol . 2006
  • 8Daniela Larisa Sandulescu,,Daniela Dumitrescu,IonRogoveanu,et al.Hybrid ultrasound imaging techniquer. World Joural of Gastroenterdogy . 2010
  • 9Nyborg WL.Safety of medical diagnostic ultrasound. Semultrasound CT MR . 2002
  • 10Frijlink M E,Goertz D E,van Damme L C,et al.Intravascular ul-trasound tissue harmonic imaging in vivo. IEEE Trans UltrasonFerroelectr Freq Control . 2006