摘要
针对夏季室内热环境情况,采用现场测试的方法,对部分教室的夏季热环境影响因素进行分析。并利用Fanger热舒适方程,用PMV(Predicted Mean Vote)———预测平均反应,为热舒适做出评价。
The method of the spot test is applied to indoor thermal environment in summer in this paper. The factors, influencing the thermal environment in summer of parts of classrooms, are analyzed, And the thermal comfortable equation, building by Fanger professor and PMV (Predicted Mean Vote) evaluation index, are used to make an evaluation for the body thermal comfortable feeling.
出处
《山西建筑》
2006年第3期174-175,共2页
Shanxi Architecture
关键词
室内热环境
温度
湿度
人体热舒适
indoors thermal environment, temperature, humidity, body thermal comfortable feeling