摘要 焦化废水中含有大量的氰化物,必须采取有效措施进行去除,传统去除方法运行成本高、操作复杂。提出了用高压毫微秒脉冲产生的非平衡等离子体处理含氰废水的方法,对其影响因素pH值、放电时间、气流量、放电条件等进行了大量的实验研究,结果表明:溶液初始pH值为9.09,放电2 h,放电电压46 kV时氰化物的去除率最高可达93.2%,氰化物质量浓度可降至0.26 mg/L。实验对比了放电与不放电氰化物的去除效果:相同条件下放电后氰化物的去除率大大提高,为焦化废水中氰化物的去除提出了一种新的方法。 There is large amount of cyanide in coking wastewater, which should be removed by some effective methods. For conventional methods, the running cost is high, and operation is complicated. A new method was proposed to treat cyanic wastewater, i.e. using non-equilibrium plasma generated by high voltage were discussed, including pH value, reaction time, air flux, and discharging indicate that while the initial pH value of solution is 9.09 and the millimicrosecond pulse. Many factors condition. The results of experiment discharge voltage is 46 kV, the removal efficiency of CN can reach 93.2%, and the concentration of CN can decrease below to 0.26 mg/L after two-hour discharge. The comparison of experiments with or without discharge demonstrates that the removal efficiency is higher with discharge than that without discharge. A new method is proposed for CN removal from coking wastewater.
出处 《水资源保护》 CAS 北大核心 2006年第1期87-91,共5页 Water Resources Protection
关键词 焦化废水 非平衡等离子体 含氰废水 coking wastewater non-equilibrium plasma cyanic wastewater
  • 相关文献

参考文献13

  • 1李亚峰,顾涛.金矿含氰废水处理技术[J].当代化工,2003,32(1):1-4. 被引量:47
  • 2JAE-DUK M.SANG-TAEK G.Discharge and ozone generation character-istics of a ferroelectric-ball/Mica-Sheet Barrier[J].IEEE Trans.Ind Applicant,1998,34(6):1206-1211.
  • 3何正浩,邵瑰玮,王万林,李劲,李胜利,杨怀远,张瑜,杜建敏.脉冲电晕放电处理焦化废水的研究[J].高电压技术,2003,29(4):29-31. 被引量:22
  • 4ABOU-GHAZALA A,KATSUKI S,SCHOENCHBACK K H,et al.Bacterial decontamination of water by means of pulsed corna discharges in[J].Pulsed Power Plasma Science,2001,1:612-615.
  • 5SUN B,MASAYUKI S,CLEMENTS J S.Use of a pulsed high-voltage discharge for removal of organic compounds in aqueous solution [J].Journal of Physics D:Applied Physics,1999,32(15):1908-1915.
  • 6DZIEWINSKI J,MARCZAK S,NUTTALL E,et al.Developing and testing electrochemical methods for treating metal salts,cyanides and organic compounds in waste streams[J].Waste Management,1998,18:257-263.
  • 7CHIANG K,AMAL R,TRAN T.Photocatalytic oxidation of cyanide;kinetic and mechanistic studies[J].Journal of Molecular Catalysis A:Chemical,2003,193:285-297.
  • 8PARGA J R,SHUKLA S S,CARRILLO-PEDROZA F R.Destruction of cyanide waste solutions using chlorine dioxide,ozone and titania sol[J].Waste Management,2003,23:183-191.
  • 9HERNANDEZ-ALONSO.MARIA D,CORONADO,et al.Ozone enhanced activity of aqueous titanium dioxide suspensions for photocatalytic oxidation of cyanide ions[J].Applied Catalysis B:Environment,2002,39:257-267.
  • 10国家环保总局.水和废水监测分析方法[M].北京:中国环境科学出版社,1989..

二级参考文献19

共引文献119

同被引文献105

引证文献10

二级引证文献96

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部