隔离病房气流分布模拟与评价 被引量:1

Simulation and evaluation of air distribution for isolation wards
在线阅读 下载PDF
导出
摘要 采用CFD数值模拟的方法,利用相关评价指标对四种不同气流分布方式进行了比较分析,认为天花板顶送异侧下排是较为理想的气流分布方式。建立了实体模型,对这种气流分布方式的排污效果进行了实验测试,结果令人满意。 Based on the CFD simulation, analyses and compares four air distribution modes using relevant evaluating indexes, and concludes that the top-supplying and opposite down.exhausting air distribution is an optimal mode for isolation wards. With a full-scale model, tests the contamination exclusion effect of the air distribution mode and the result is satisfactory.
机构地区 同济大学
出处 《暖通空调》 北大核心 2006年第1期8-12,70,共6页 Heating Ventilating & Air Conditioning
基金 上海科委科技攻关课题"医院空调系统防范非典型肺炎病毒传播与感染应急措施与今后对策研究"(编号:03DZ19614)的子课题
关键词 隔离病房 气流分布 数值模拟 项送异侧下排 实验 isolation ward, air distribution, numerical simulation, top-supplying and opposite downexhausting, experiment
  • 相关文献

参考文献11

二级参考文献64

  • 1王红朝.对《医院病房防SARS抗菌干盘管空调系统研究》一文的质疑[J].暖通空调,2004,34(8):30-34. 被引量:7
  • 2沈晋明,唐喜庆.上海医院发热门诊改造[J].中国医院建筑与装备,2004,5(2):6-10. 被引量:4
  • 3梅自力.医院建筑空调设计[M].北京:中国建筑工业出版社,1991..
  • 4沈晋明.合理确定通风空调系统中新风量[A]..空调设计(1)[C].湖南:湖南大学出版社,1997.27—33.
  • 5沈晋明.空气过滤器及其应用[A]..空气净化研讨会论文集[C].,2001.108-111.
  • 6沈晋明 黄霞.生物安全技术与微生物控制[A]..暖通空调新技术4[C].北京:中国建筑工业出版社,2002.1—4.
  • 7李芄 沈晋明.高档商业建筑室内空气品质改善措施的适用性研究[A]..全国暖通空调制冷2002年学术年会文集[C].,2002.79—102.
  • 8沈晋明 许钟麟.采用生物洁净技术控制空调系统的微生物污染[A]..第五届中国国际(北京)洁净技术论坛暨展览[C].北京,2002.23—29.
  • 9沈晋明 贺舒平 孙光前.循环风式紫外线消毒器结构工艺设计[J].上海城建学院学报,1993,(4):50-55.
  • 10[15]Li, Y, Delsante, A and Symons, Residential kitchen range hoodsbuoyancy-capture principle and capture efficiency revisited [J].Indoor Air, 1997, 7:151-157

共引文献76

同被引文献14

  • 1唐喜庆,沈晋明,邓伟鹏,李春.送风口对传染性隔离病房室内定向气流的影响[J].建筑热能通风空调,2005,24(4):11-18. 被引量:6
  • 2BAUMAN F,FAULKNER D,ARENS E A,et al.Air movement,ventilation,and comfort in a partitioned office space[G]∥ASHRAE Trans,1992,98(1):756-780.
  • 3CHOW W K,TSUI K F.Airflow studies in a forced ventilated chamber with low partitions[G]∥ASHRAE Trans,1995,101(2):125-135.
  • 4GILKESON C A,CAMARGO-VALERO M A,NOAKES C J,et al.Measurement of ventilation and airborne infection risk in large naturally ventilated hospital wards[J].Building&Environment,2013,65(7):35-48.
  • 5CHING W H,LEUNG M K H,LEUNG D Y C,et al.Reducing risk of airborne transmitted infection in hospitals by use of hospital curtains[J].Indoor&Built Environment,2008,17(3):252-259.
  • 6LEE H,AWBI H B.Effect of internal partitioning on room air quality with mixing ventilation-statistical analysis[J].Renewable Energy,2004,29(10):1721-1732.
  • 7SCANLON T J,STICKLAND M T.Coughgenerated aerosols of mycobacterium tuberculosis[J].American Journal of Respiratory&Critical Care Medicine,2004,169(5):604-609.
  • 8COX C S.Physical aspects of bioaerosol particles[M]∥Bioaerosols handbook.London:Lewis Publishers,1955:15-25.
  • 9CHANG T J,HU T S.Transport mechanisms of airborne particulate matters in partitioned indoor environment[J].Building&Environment,2008,43(5):886-895.
  • 10ZHANG Z,CHEN Q.Experimental measurements and numerical simulations of particle transport and distribution in ventilated rooms[J].Atmospheric Environment,2006,40(18):3396-3408.

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部