摘要 用光离子作检测器的便携式气相色谱仪,在现场对空气中苯系物进行定性、定量分析,为解决环境污染提供技术数据。操作方法简单,灵敏度高,重复性好、适用范围广,对空气中苯系物的最低榆出质量分数分别为:苯0.03×10^-6、甲苯0.05×10^-6、乙苯10×10^-6、对二甲苯1×10^-6、邻二甲苯1×10^-6,各组分变异系数均在4.5%-5.8%,方法精密度较好。本方法可用于应急事故中空气中苯系物进行定量。 Portable gas-phase chromatograph of optical ionic detector was used to qualitative and quantitative analysis of the benzene family material content in the air on the spot. This provided technique data for the solving of cnviroment pollution. The operation of the method is easy, the sensitivity is high, the repeatability is good and the scope of application is wide. The benzene family material minimum determination mass fraction in the air is benzene 0.03×10^-6 ,methylbenzene 0.05×10^-6, ethylbenzene 1 ×10^-6 ,p-xylene 1×10^-6 ,o-xylene 1×10^-6. The coefficent of variation of each component is 4.5% -5.8%. The precision of the method is better. The method can be applied to the quantitative of benzene family material in emergency accident.
出处 《聚酯工业》 CAS 2006年第1期42-44,共3页 Polyester Industry
关键词 苯系物 检测 光离子检测器 benzene family material determination optical ionic detector
  • 相关文献

参考文献1

  • 1HuberJFK GerritseRG.保留指数与进样量的关系[J].J Chromatogr,1971,58(2):137-158.

同被引文献25

  • 1杨锦发.生态地球化学土壤样品高精度测试与质量监控[J].上海地质,2006(4):48-51. 被引量:5
  • 2H-l25,1-2014.场地环境调查技术导则[S],2014.
  • 3DD2014-06.污染场地土壤和地下水调查与风险评价规范[S],2014.
  • 4Zhou Y Y, Yu J F, Yah Z G. Application of portable gas chromatography-photo ionization detector combined with headspace sampling for field analysis of benzene, toluene, ethylbenzene, and xylene in soils[J]. Environmental Monitoring andAssessment, 2013,185(4):3037-3048.
  • 5McAndrews B, Heinze K, DiGuiseppi W. Defining TCE plume source areas using the membrane interface probe (MIP)[J]. Soil & Sediment Contamination, 2003,12(6):799-813.
  • 6Rogge M, Christy T M, De W F. Site contamination fast delineation and screening using the membrane interface probe[R]. Field Screening Europe 2001, 2002: 91-98.
  • 7McCall, Wesley, Christy, et al. Field application of the combined membrane-interface probe and hydraulic profiling tool (MiHpt)[J]. Ground Water Monitoring and Remediation, 2014,34(2):86-96.
  • 8McComb, Jacqueline Q, Rogers, et al. Rapid screening of heavy metals and trace elements in environmental samples using portable X-ray fluorescence spectrometer, a comparative study[J]. WaterAir and Soil Pollution, 2014,225(12):2169.
  • 9Bosco G L. Development and application of portable, hand- held X-ray fluorescence spectrometers[J]. Trends in Analytical Chemistry, 2013,45:121-134.
  • 10钱建平,吴高海,陈宏毅.便携式X射线荧光光谱仪应用条件试验及效果[J].物探与化探,2010,34(4):497-502. 被引量:16