摘要
采用发射光谱仪PDA法定量测定钢中的酸溶铝是完全可行的,与传统的化学分析方法相比具有快速、成本低的优点,完全满足炉前快速分析的要求,效果理想。
The article demonstrates that it's fully feasible to mensurate acid soluble aluminum contained in steel by means of emission spectrum PDA method, which possesses the advantages of rapidness and low cost compare to traditional chemical analysis method, and adequate to fulfill faster analysis directly from the furnace, the effect is as desired.
出处
《一重技术》
2005年第6期13-14,共2页
CFHI Technology
关键词
发射光谱法
PDA
酸溶铝
痕量元素
emission spectrum method
PDA
acid soluble aluminum
trace element