摘要 建立了一个理想的完全约束的钢筋混凝土柱模型,并采用这个模型对实际结构中轴心受压柱的耐火极限进行了预测和分析。研究结果表明,在截面尺寸、纵筋配筋率、保护层厚度及混凝土抗压强度等诸多因素中,保护层厚度是影响实际结构中轴心受压柱的耐火极限的最主要因素。而我国现行的设计防火规范是以截面尺寸为主要指标对钢筋混凝土柱的耐火极限进行规定,因此,建议我国的设计防火规范对钢筋混凝土柱的耐火极限进行规定时加入对保护层厚度的要求,同时建议加入防止柱表面爆裂的措施。 An ideal model of a totally restrained reinforced concrete column is proposed in this paper. Based upon the model, the limit of fire resistance of a restrained column in a system is predicted and analyzed. It is concluded that the concrete cover is the main factor affecting the limit of fire resistance of reinforced concrete columns under axial load. So it is suggested that code of China for fire protection design take the concrete cover into consideration on the regulation of reinforced concrete columns. And the regulations on preventing fire - exposed concrete from spalling should be included.
出处 《铁道科学与工程学报》 CAS CSCD 北大核心 2005年第5期36-40,共5页 Journal of Railway Science and Engineering
基金 湖南省建设厅重点资助项目(湘建科(2004)-16)
关键词 约束 钢筋混凝土 耐火极限 restraint reinforced concrete columns limit of fire resistance
  • 相关文献

参考文献10

  • 1Franssen J M, Dotreppe J C. Fire resistance of columns in steel frames [J]. Fire Safety Journal,1992,19(2-3):159-175.
  • 2Cabrita Neves I. The critical temperature of steel columns with restrained thermal elongation [J]. Fire Safety Journal,1995,24(3):211-227.
  • 3Poh K W, Bennetts I D. Behaviour of steel columns at elevated temperature [J]. Journal of structural engineering(ASCE),1995,121(4):676-684.
  • 4Valente J C, Cabrita Neves I. Fire resistance of steel columns with elastically restrained axial elongation and bending [J]. Journal of Constructional Res,1999,52(3):319-331.
  • 5Rodrigues J P C, Cabrita Neves I, Valente J C. Experimental research on the critical temperature of compressed steel elements with restrained thermal elongation [J]. Fire Safety Journal,2000,35(2):77-98.
  • 6Ali F,O'connor D. Structural performance of rationally restrained steel columns in fire[J]. Fire Safety Journal,2001,36(7):679-691.
  • 7Franssen J M. Failure temperature of a system comprising a restrained column submitted to fire [J].Fire Safety Journal,2000,34(2):191-207.
  • 8GB50010-2002.混凝土结构设计规范[S].[S].,..
  • 9过镇海 时旭东.钢筋混凝土的原理和分析[M].北京:清华大学出版社,2002..
  • 10GB50045-95.高层民用建筑设计防火规范[S].[S].中华人民共和国公安部,..