摘要
A temperature measurement model of radiation thermometry for the surface covered by participating media was developed. The model was based on the radiation heat transfer of participating media and principles of radiation pyrometers, and solved by integral formulation of discrete ordinate method on spectral waveband. The influence of water mist on the indicated temperature of Raytek MR1SB one/two color pyrometer was discussed. Mie theory was used to calculate the radiative properties of water mist. In order to verify the model, a laboratory temperature measurement experiment was executed. The result shows that temperature of radiation thermometry is sensitive to the spectral response wavelength of pyrometer, and the simulated temperature of pyrometer agrees well with the experimental measurements on a suitable wavelength. The simulated temperature was lower than the real temperature of surface for one-color pyrometer, and it could be higher or lower than the real one for two-color pyrometer with the influence of participating media.
基金