摘要 AIM: To investigate whether the routine use of fibrin glue applied onto the hepatic resection area can diminish postoperative volume of bloody or biliary fluids drained via intraoperatively placed perihepatic tubes and can thus lower the complication rate.METHODS: Two groups of consecutive patients with a comparable spectrum of recent hepatic resections were compared: (1) 13 patients who underwent application of fibrin glue immediately after resection of liver parenchyma;(2) 12 patients who did not. Volumes of postoperative drainage fluid were determined in 4-h intervals through 24 h indicating the intervention caused bloody and biliary segregation.RESULTS: Through the first 8 h postoperatively, there was a tendency of higher amounts of fluids in patients with no additional application of fibrin glue while through the following intervals, a significant increase of drainage volumes was documented in comparison with the first two 4-h intervals, e.g., after 12 h, 149.6 mL +/-110 mL vs 63.2 mL +/-78 mL. Using fibrin glue, postoperative fluid amounts were significantly lower through the postoperative observation period of 24 h (851 mL +/-715 mL vs 315 mL +/-305 mL).CONCLUSION: For hepatic resections, the use of fibrin glue appears to be advantageous in terms of a significant decrease of surgically associated segregation of blood or bile out of the resection area. This might result in a better outcome. AIM: To investigate whether the routine use of fibrin glue applied onto the hepatic resection area can diminish postoperative volume of bloody or biliary fluids drained via intraoperatively placed perihepatic tubes and can thus lower the complication rate. METHODS: Two groups of consecutive patients with a comparable spectrum of recent hepatic resections were compared: (1) 13 patients who underwent application of fibrin glue immediately after resection of liver parenchyma; (2) 12 patients who did not. Volumes of postoperative drainage fluid were determined in 4-h intervals through 24 h indicating the intervention caused bloody and biliary segregation. RESULTS: Through the first 8 h postoperatively, there was a tendency of higher amounts of fluids in patients with no additional application of fibrin glue while through the following intervals, a significant increase of drainage volumes was documented in comparison with the first two 4-h intervals, e.g., after 12 h, 149.6 mL +/-110 mL vs 63.2 mL +/-78 mL. Using fibrin glue, postoperative fluid amounts were significantly lower through the postoperative observation period of 24 h (851 mL +/-715 mL vs 315 mL +/-305 mL). CONCLUSION: For hepatic resections, the use of fibrin glue appears to be advantageous in terms of a significant decrease of surgically associated segregation of blood or bile out of the resection area. This might result in a better outcome.
机构地区 Department of Surgery
出处 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第38期5984-5987,共4页 世界胃肠病学杂志(英文版)
关键词 Fibrin glue Hepatic resection 肝切除术 肝纤维化 血液流变性 病理机制
  • 相关文献

参考文献7

  • 1[1]Lippert H,Scheele J.Lebertumoren.In:Lippert H (ed.) Praxis der Chirurgie,Allgemein-und Viszeralchirurgie.1st ed.Stuttgart,New York:Thieme 1998:549-562
  • 2[2]Kockerling F,Schneider C,Scheidbach H,Hohenberger W.Stellenwert der Fibrinklebung in der Leberchirurgie.In:Kockerling F (ed.) Leberchirurgie.1st ed.Heidelberg,Leipzig:Johann Ambrosius Barth 1999:103-108
  • 3[3]Ringe B.Gewebeklebung in der hepatobiliaren und Transplantationschirurgie.In:Ringe B (ed.) Gewebeklebung in der Chirurgie:Grundlagen und Anwendung.1st ed.Stuttgart,New York:Thieme 2001:63-75
  • 4[4]Nakajima Y,Shimamura T,Kamiyama T,Matsushita M,Sato N,Todo S.Control of intraoperative bleeding during liver resection:analysis of a questionnaire sent to 231 Japanese hospitals.Surg Today 2002;32:48-52
  • 5[5]Davidson BR,Burnett S,Javed MS,Seifalian A,Moore D,Doctor N.Experimental study of a novel fibrin sealant for achieving haemostasis following partial hepatectomy.Br J Surg 2000;87:790-795
  • 6[6]Turner AS,Parker D,Egbert B,Maroney M,Armstrong R,Powers N.Evaluation of a novel hemostatic device in an ovine parenchymal organ bleeding model of normal and impaired hemostasis.J Biomed Mater Res 2002;63:37-47
  • 7[7]Martis G,Miko I,Szendroi T,Kathy S,Kovacs J,Hajdu Z.Results with collagen fleece coated with fibrin glue (TachoComb).A macroscopical and histological experimental study.Acta Chir Hung 1997;36:221-222