期刊文献+

中小型同步发电机失步原因分析与防止措施 被引量:2

Analysis and Preventing for Desynchronizing Cause of Medium & Small-sized Synchro-generator
在线阅读 下载PDF
导出
摘要 为了确保同步发电机稳定运行于最大功率角状态,又不发生失步,通过对中小型同步发电机失步原因的静态分析和动态分析,提出了如何确保同步发电机稳定运行于最大功率角状态而不失步的方法。并对龙溪水电站机组进行了最大功率角限值的具体测量,使机组在最大功率角状态下安全、连续、稳定运行成为现实。因此,龙溪水电站于2000年成为台州电网第一家按电压考核的水电站,每年可减少因无功功率扣款近100万元。 To ensure the synchro-generator running steadily at the stage of max. power angle without causing any failure, and fully utilize the water resources and to soften the current electricity shortage, we hereafter claim for the method ensuring the synchro -generator running steadily at the stage of max. power angle by static & dynamic analysis, furthermore, to realize the fact of safely, continuously and steadily operation under improving power angle through our carefully measuring the limitation of max-power angle to Longxi generator set. Hence, in year 2000, Longxi Water Power Station was awarded as the first one scored by voltage in Taizhou, which can save around one million RMB annually.
出处 《机电工程》 CAS 2005年第9期58-61,共4页 Journal of Mechanical & Electrical Engineering
关键词 同步发电机 功率角 极限 失步 稳定 synchro-generator power angle limitation desynchronizing steady
  • 相关文献

参考文献2

  • 1(日)电力系统稳态性专门委员会 关根泰次.电力系统稳定性问题与对策[M].北京:水利电力出版社,1994..
  • 2翁思义 杨平.自动控制理论[M].北京:中国电力出版社,2001年..

同被引文献7

引证文献2

二级引证文献4

相关作者