摘要 Based on the one-dimensional and unsteady-state Krogh model, this paper investigates mass transfer of artificial kidney under three blood cycle modes during the course of hemodialysis. The variations of the permeable solute clearance with increasing time and the dialysis time with increasing blood flux are simulated in detail,and then one optimal blood cycle mode is acquired. The results are very important to improve the clinical dialysis efficiency of artificial kidney. Based on the one-dimensional and unsteady-state Krogh model, this paper investigates mass transfer of artificial kidney under three blood cycle modes during the course of hemodialysis. The variations of the permeable solute clearance with increasing time and the dialysis time with increasing blood flux are simulated in detail ,and then one optimal blood cycle mode is acquired. The results are very important to improve the clinical dialysis efficiency of artificial kidney.
出处 《Chinese Journal of Biomedical Engineering(English Edition)》 2005年第2期65-71,共7页 中国生物医学工程学报(英文版)
基金 The project supported by the National Natural Science Foundation of China (5016016) and Natural Science Foundation of AnhuiProvince(03043717)
关键词 Hollow fiber Artificial kidney Mass transfer Unsteady state Blood cycle mode 血液循环 循环方式 人工肾 血行转移 生物技术
  • 相关文献

参考文献1

二级参考文献11

  • 1Jaffrin M,Ding L,Laurent J.Simultaneous convective and diffusive mass transfers in a hemodialyzer[].Journal of Biomechanical Engineering Transactions of the ASME.1990
  • 2Wpper A,Woermann D,Dellanna F et al.Retrofilration rates in high-flux fiber hemodialyzers: analysis of clinical data[].Journal of Membrane Science.1996
  • 3Liao,Z.J.Numeric al ande xperimen ta lstudiesofma sst ransferinhemodial yzerandhemodialysis,Ph[]..2002
  • 4Jaffrin,M.Convectivemasstransferinhemodialysis[].Artificial Organs.1995
  • 5T.A.K. Sadiq,S.G. Advani,R.S. Parnas.Experimental investigation of transverse flow through aligned cylinders[].International Journal of Multiphase Flow.1995
  • 6Toshiaki Osuga, Takayuki Obata, Hiroo Ikehira, Shuji Tanada, Yasuhito Sasaki &amp,Hidemune Naito.Dialysate Pressure Isobars in a Hollow-Fiber Dialyzer Determined from Magnetic Resonance Imaging and Numerical Simulation of Dialysate Flow[].Artificial Organs.1998
  • 7O. Kedem,A. Katchalsky.Thermodynamic analysis of the permeability of biological membranes to non electrolytes[].Biochimica et Biophysica Acta.1958
  • 8R. P. Wendt E. Klein E. H. Bresler F. F. Holland R. M. Serino and H. Villa.Sieving properties of hemodialysis membranes[].Journal of Membrane Science.1979
  • 9PATANKAR SV.Numerical Heat Transfer and Fluid Flow[]..1980
  • 10ZhangGuoliang,ZhangGang,ZhangFengb ao etal.Stu dy onma sstransf ercharacteristi cs ofcombin edhemodialysis-hemope r-fusi onsystem[].ChineseJourn alofBiomedicalEngineering.2001