摘要
系统地整理总结了美国色谱定氮仪在长期使用过程中出现的部分问题和故障及其检查与处理方法,有效地保证了仪器的正常运转和最大利用率。
The partial problem and failure during operation as weu as their examination and disposal of U.S leco TN-314 chrometic nitrogen content meter has been collected and summed up systematically,and the normal operation and perfect usage of the unit obtained
出处
《钢铁研究》
CAS
1996年第2期40-43,共4页
Research on Iron and Steel
关键词
色谱定氮仪
故障
检查
处理
chromatic ni-content meter failure examination and disposal