期刊文献+

氢化物发生-电感耦合等离子体原子发射光谱法测定环境样品中的痕量硒 被引量:8

DETERMINATION OF TRACE SELENIUM IN ENVIRONMENTAL SAMPLES BY HYDRIDE GENERATION INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY
在线阅读 下载PDF
导出
摘要 采用氢化物发生-电感耦和等离子体原子发射光谱法(HG-ICP-AES)研究测定Se(Ⅳ), Se(Ⅵ)的方法,系统地考察了酸介质、 NaBH4浓度及共存元素的影响,建立了干扰消除的方法,确定了最佳测定条件.Se(Ⅳ), Se(Ⅵ)的检出限为0.5μg·L-1,线性范围0~0.1mg·L-1.用环境标准物质进行对照,其测定值均在给定的标准范围内. A method to determine the content of selenium(Ⅳ) and selenium(Ⅵ) by hydride generation inductively coupled plasma atomic emission spectrometry is established. The influences of acidic medium, the concentration of NaBH4 and other concomitant elements are examined systemically. Methods to eliminate interferences are developed. The optimal analytical conditions are discussed and examined. The detection limit of Se(Ⅳ) and Se(Ⅵ) is 0. 5 μg·L^-1, the linear range is 0- 0. 1 mg·L^-1. The value of selenium content detected in standard environmental sample is consistent with the standard value.
出处 《北京师范大学学报(自然科学版)》 CAS CSCD 北大核心 2005年第4期389-392,共4页 Journal of Beijing Normal University(Natural Science)
关键词 Se(Ⅳ) Se(Ⅵ) 氢化法 电感耦合等离子体原子发射光谱法 痕量分析 selenium(Ⅳ) selenium(Ⅵ) hydride generation inductively coupled plasma atomic emission spectrometry, trace analysis
  • 相关文献

参考文献4

二级参考文献18

共引文献23

同被引文献224

引证文献8

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部