摘要 本采用萃取色谱法,以P507萃淋树脂为固定相,以HCl-NH4Cl体系为淋洗液,研究了高纯Nd2O3(99.999%~99.9999%)中稀土杂质与Nd基体的分离方法。选择螯合剂-活性碳柱富集淋洗液中痕量稀土,采用火花源质谱法分析,测定下限0.01μg/g。 The separation of rare earths impurities in high purity Nd2O3 have been carried out with P507 extraction chromatograpby hydrochloric acid-ammonium chloride as eluant.The method of preconcentration and the determination conditions of spark source mass spectromatry have been selected.The determination requirement of rare earths impurities in 99.9999% Nd2O3 is achieved.
出处 《质谱学报》 EI CAS CSCD 1996年第1期56-62,共7页 Journal of Chinese Mass Spectrometry Society
关键词 萃取 色谱分离 质谱 氧化钕 稀土 P_(507)extraction chromatography,high purity Nd_2O_3,spark source mass spectrometry
  • 相关文献

参考文献6

  • 1王星堂,新疆大学学报,1989年,6卷,2期,71页
  • 2陆少,中国稀土学报,1989年,7卷,1期,68页
  • 3王振茎,中国稀土学报,1989年,6卷,1期,89页
  • 4李水兰,中国环境监测,1988年,4卷,4期,25页
  • 5彭春霖,分析试验室,1987年,6卷,1期,6页
  • 6卜国光,理化检验,1987年,23卷,1期,31页