GB 18580-2001与EN 120:1992穿孔法测定人造板甲醛释放量的比较与分析 被引量:4

Contrast of GB18580-2001 & EN 120-Extraction Method of Formaldehyde Content Determination for Wood-based Panel Products ( known as perforator method )
在线阅读 下载PDF
导出
摘要 对GB 18580-2001《室内装饰装修材料人造板及其制品中甲醛释放限量》中采用的穿孔萃取法和欧洲标准EN 120:1992《Wood-based panel products Determination ot formaldehyde content Extraction method(known as perforator method)》(以下简称EN 120)中的穿孔萃取法进行方法对比和试验结果比较, 提出修改GB 18580-2001中采用的穿孔萃取法,建议等同采用EN 120:1992中的穿孔萃取法。 A comparison was made between the two standard extration methods of determination of formaldehyde content for wood-based panel products (known as perforator methods) specified in GB 18580-2001 and in EN 120, Based on the results , the authors suggest that the extraction method of GB 18580-2001 be revised to adopt the extraction method of EN 120 equivalently.
出处 《人造板通讯》 2005年第9期16-18,共3页 Wood-Based Panels
关键词 木质人造板 甲醛释放 穿孔萃取法 数据偏差 wood-based panel formaldehvde emisson extraction method (perforator method) data deviation
  • 相关文献

参考文献2

  • 1GB/T 17657-1999.人造板及饰面人造板理化性能试验方法[S],1999.
  • 2GB 18580-2001.室内装饰装修材料 人造板及其制品中甲醛释放限量[S],2001.