本文介绍了“砖墙与破剪力培混合结构八层住宅1:4模型”的抗震试验。试验研究表明,在“砖墙与砼剪力墙混合结构”中,两种墙体如配置得当,可以具有较好的协同工作性能和抗震性能。
The paper presents aseismic test of a 1:4 scale model of 8-story dwelling construction with brick walls and concrete shear walls combined.The result shows that the two kinds of walls combined work harmoniously and have good aseismic performances if they are designed propertly.