MR导向冷冻消融猪肾脏的动态影像学研究 被引量:2

Dynamic imaging study after MR-guided cryoablation in a porcine model
暂未订购
导出
摘要 目的:评价冷冻消融对猪肾实质、肾脏微循环、集合系统的影响,为临床冷冻消融肾脏肿瘤的可行性及安全性提供实验理论依据。方法:五指山小型实验猪实验组6头,ipath200光学系统导引下1.47mm氩氦冷冻探针植入集合系统周围,冻融两个循环;对照组2头,仅行穿刺。术中动态监测冰球形成情况。术后1天、14天、30天分别行1.5T高场磁共振检查。结果:实验猪均穿刺并冷冻消融成功。冷冻10min,冰球最大并大部分位于靶组织内,显示为椭圆形极低信号影。术后1.5TMR显示靶区组织T1WI、T2WI均呈低信号伴周围不连续的斑片状高信号出血带。周围可见水肿信号。注入GD-DTPA后,冷冻中心无明显强化,周边见均匀强化环。结论:MR导向穿刺准确率高,未发现继发于冷冻的集合系统损伤,对于小肾癌、局限性的累及集合系统的肾肿瘤安全可行。 Objective:To determine the effect of cryoablation on renal parenchyma,renal microcirculation and collecting system in the porcine kidney.This experiment showed theoretical basement for the safety and efficacy of renal tumor cryoablation.Methods:Eight wuzhishan pig inbreeding line(WZSP) were divided into two groups,the experiment group included 6 swine which were treated with cryoablation procedures under the guidance of optical tracking system(iPath 200,Philips Medical System).Cryoablation was performed using a high-pressure argon system(Cryo-Hit system) with a double freeze/thaw cycle.A 1.47 mm MR-compatible cryoprobe was advanced into the target near the collecting system;The control group two swine,only puncture.The iceball can be tracked dynamically during the procedure.Follow-up dynamic MR imagings were obtained after 1,14 and 30 days of the operation.Results:In the animal experiments,the puncture was successful in all 8 cases.10 minutes after freezing,the iceball was mostly located in the target tissue with the largest diameter,appear as oval-shaped low signal.1.5T T1WI and T2WI of the target tissue after the protocol showed low signal with discontinuous patchy high signal(ribbon bleeding area),surrounding edema signal.After the injection of GD-DTPA,homogeneous enhancement ring can be seen around the iceball without center enhancement.Conclusion:MR-guided puncture is of high accuracy.No evidence of damage to the renal collecting system secondary to freezing is found.These data have clinical relevance for treatment of a small,localized,central renal tumor in proximity to the pelvicaliceal system without damage to the collecting system.
出处 《医学影像学杂志》 2012年第2期253-256,共4页 Journal of Medical Imaging
关键词 肾脏 冷冻术 磁共振成像 Kidney Swine Cryosurgery Magnetic reasonance imaging
  • 相关文献

参考文献4

二级参考文献43

  • 1Wolfgang Jungraithmayr,Dieter Burger,Manfred Olschewski,Stefan Eggstein.Cryoablation of malignant liver tumors: results of a single center study[J].Hepatobiliary & Pancreatic Diseases International,2005,4(4):554-560. 被引量:27
  • 2于立新,徐健,白喜文,罗永礼,马俊杰.新鲜尸体肾血管的解剖观测及其在肾移植的应用[J].中国临床解剖学杂志,1993,11(4):281-282. 被引量:4
  • 3郑思竞.中国人体质调查[M].上海:上海科学技术出版社,1990.294-296.
  • 4Kingler HC, Kramer G, Lodde M, et al. Stone treatment and coagulopathy. European Urology, 2003, 43(1):75-79
  • 5Yilmaz E, Ozcan S, Basar M, et al. Role of adjunctive medical therapy with infedipine and deflazacort after extracorporal shock wave lithotripsy of ureteral stone.Urology, 2002, 59(6):835-838
  • 6Van der Eecken H, Schatteman P, Carpentier P, et al.Major intra-abdominal complications following extracorporeal shockwave lithotripsy (ESWL) in a patient with EhlersDanlos Syndrome. European Urology, 2002, 42(6):635-636
  • 7Willis LR, Evan AP, Connors BA, et al. Relationship between kidney size, renal injury, and renal impairment induced by shock wave lithotripy. J AM Soc Nephrol, 1999,10(3): 1753-1762
  • 8Willis LR, Evan AP, Lingeman JE. The import of highdose lithotripsy on renal function. Contemporary urol, 1999,14(4):45-50
  • 9O'Hagen KP, Zambraski EJ. Kidney function in deoxycorticosterone acetate (DOCA) treated hypertensive Yucatan miniature swine. In: Tumbleson ME, eds. Swine in biomedical research. New York: plenum, 1986.1779-1787
  • 10Paterson RF, Lingeman JE, Evan AP, et al. Percutaneous stone implantation in the pig kidney: a new animal model for lithotripsy research. J Endorol, 2002, 16(4):543-547

共引文献29

同被引文献10

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部