期刊文献+

前瞻性心电门控技术在双源CT冠状动脉成像中的应用价值 被引量:8

Application value of prospective electrocardiogram-gating for dual-source CT coronary angiography
暂未订购
导出
摘要 目的:比较双源CT冠状动脉成像(CTCA)前瞻性心电门控与回顾性心电门控扫描的辐射剂量及图像质量。方法:以相同纳入标准,选取50例行前瞻性心电门控扫描的患者作为前瞻门控组,另选取50例行回顾性心电门控的患者作为回顾门控组。由两名CT医师分别对两组CTCA图像进行评估。记录并比较两组患者一般临床资料、辐射剂量及图像质量评分。结果:两组患者性别、年龄、体重指数、平均心率、心率波动、扫描范围差异均无统计学意义(P>0.05)。前瞻门控组有效辐射剂量(3.80±0.46)mSv,回顾门控组有效辐射剂量(20.64±3.14)mSv,两组差异具有统计学意义(P<0.001)。两组图像质量的差异无统计学意义(2=1.166,P=0.761)。结论:前瞻性心电门控较回顾性心电门控技术能够在保证图像质量的同时明显降低辐射剂量。 Objective:To compare radiation dose and image quality between prospective and retrospective ECG-gating CT coronary angiography(CTCA) with dual-source CT.Methods:A tota l of 100 patients with heart rate less than 70 beats per minute were selected in same standard,50 patients underwent CTCA using prospective ECG-gating as prospective group,another 50 patients underwent CTCA using retrospective ECG-gating as retrospective group.Two independent radiologists assessed the image quality of CTCA used blinding method.General clinical information,scan range,effective radiation dose and image quality were recoded and compered between two group.Results:Sexaul,age,body mass index,heart rate,heart rate variability and scan range between two group had no significant difference(P>0.05).The average effective dose of prospective group and retrospective group was(3.80±0.46) mSv and(20.64±3.14) mSv,respectively(P<0.001).No significant difference of image quality was found between two groups(X2=1.166,P=0.761).Conclusion:Prospective ECG-gating CTCA can effectively reduce radiation dose without compromising image quality.
出处 《医学影像学杂志》 2012年第2期178-181,共4页 Journal of Medical Imaging
关键词 心电门控 冠状动脉成像 体层摄影术 X线计算机 辐射剂量 Electrocardiogram gating Coronary angiography Tomography,X-ray computed Radiation dose
  • 相关文献

参考文献2

二级参考文献18

  • 1孟冷,张兆琪,吕飙.64层螺旋CT在冠状动脉疾病诊断中的价值[J].中华放射学杂志,2006,40(8):792-796. 被引量:130
  • 2Dill T,Deetjen A,Ekinci O,etal.Radiation dose exposure in muhislice computed tomngraphy of the coronaries incomparison with conventional coronary angiography,Int J Cardiol,2008,124:307-311.
  • 3Coles DR,Smail MA,Negus IS,et al.Comparison of radiation doses from multislice computedtomography coronary angiography and conventional diagnostic angiography.J Am CoilCardiol,2006,47:1840-1845.
  • 4Raff GL,Gallngher MJ,O'Neill WW,et al.Dingnostic accuracy of noninvasive coronaryangingraphy using 64-slice spiral computed tomography.J Am Coil Cardiol,2005,46:552-557.
  • 5McCollough CH,Primak AN,Saba O,et al.Dose performance of a 64-channel dual-source CTscanner.Radiology,2007,243:775-784.
  • 6Einstein AJ,Henzlova MJ,Rajagopalan S.Estimating risk of cancer associated withradiation exposure from 64-slice computed tomography coronaryangiography.JAMA,2007,298:317-323.
  • 7Abada HT,Larchez C,Daoud B,et al.MDCT of the coronary arteries:feasibility of low-doseCT with ECG-pulsed tube current modulation to reduce radiationdose.AJR,2006,186:S387-S390.
  • 8Austen WG,Edwards JE,Frye RL,et al.A reporting system on patients evaluated forcoronary artery disease.Report of the Ad Hoe Committee for Grading of Coronary ArteryDisease,Council on Cardiovascular Surgery,American Heart Association.Circulation,1975,51(4 Suppl):5-40.
  • 9Bax JJ,Schuijf JD.Which patients should be referred for noninvasive angiography withmuhi-slice CT? Int J Cardiol,2007,114:1-3.
  • 10Brenner DJ,Hall EJ.Computed tomography:an increasing source of radiation exposure.NEngl J Mad,2007,357:2277-2284.

共引文献60

同被引文献65

引证文献8

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部