摘要
1987年6月至1993年6月采用自制球囊导管及其配套器械行经皮球囊导管二尖瓣分离术(PBMC)410例,99.5%成功,108例随访38±l4月,70%心功能稳定于NYHAⅠ级,6例(5.5%)发生再狭窄,3例死亡。本文详细介绍了PBMC病例选择、方法学及操作技巧诸方面的经验和体会。
Abstract From June 1987 to June 1993 by a domestic balloon catheter percutaneous balloon catheter mitral commissurotomy(PBMC)was performed in 410 cases,of which 408 (99.5%) the procedure has been successful.108 cases followed up 38 ±14 months, of which in 70% cardiac function remained stable in NYHA class 1,in 6 (5.5%) had mitral restenosis,and in 3 death occurred.The present article introduced the experience and understanding on the selection of cases,methodology and skill for PBMC in detail.
出处
《中国介入心脏病学杂志》
1995年第1期6-9,共4页
Chinese Journal of Interventional Cardiology