期刊文献+

土工膜渗漏检测系统的开发 被引量:8

Development of New Leakage Detection System in Geomembrane
在线阅读 下载PDF
导出
摘要 通过比较国外多种填埋场渗漏检测方法,成功地研制了基于高压直流电法的渗漏检测系统。该系统利用CAN总线技术,解决了由于填埋场检测面积大所带来的采集数据量大、传输距离远的问题;利用低频脉冲供电方式,将正负半周采集的数据相减,大大减小了低频地电噪声的影响;通过建立合理的地电模型,解决了非均匀介质条件下的电势分布问题,进而提高了系统的检测精度。通过实践检验,表明该系统在检测电极间距为4m时,误差超过0.4m的概率低于10%。 A new leakage detection system based on high voltage DC method was successfully developed through comparison among foreign methods used in landfill leakage detection. The system uses CAN bus technology and successfully shoots the difficulties of massive data collection and long distance transmission caused by spreading detection area. The low-frequency pulse powering mode is applied and the data collected when supply power is positive and negative are subtracted, which greatly reduces the background noise. Through setting up reasonable earth-electricity model, the distribution problem of electrical potential in uneven medium is resolved and system detection accuracy is improved. The field tests show that the probability of detection error over 0.4 m is no more than 10% , when the space between detection electrodes is 4 m.
出处 《环境科学研究》 EI CAS CSCD 北大核心 2005年第4期67-70,共4页 Research of Environmental Sciences
基金 国家高技术研究发展计划项目(2001AA644010)
关键词 土工膜 渗漏检测 地电模型 geomembrane leakage detection earth-electricity model
  • 相关文献

参考文献5

  • 1梁爽.瞬变电磁法仪器研制中的噪声抑制问题[J].煤田地质与勘探,2004,32(1):51-54. 被引量:10
  • 2Darilek G T,Laine D L.Costs and benefits of geomembrane liner installation CQA[Z].Geosynthetics'2001 Conference Proceedings,Portland,Oregon,USA,2001.
  • 3王斌,王琪,董路,薛咏海.垃圾填埋场人工衬层渗漏的电学法检测研究[J].环境科学研究,2004,17(4):63-66. 被引量:14
  • 4Darilek G T,Laine D L.Performance-based specification of electrical leak location surveys for geomembrane liners[Z].Geosynthetics'99 Conference Proceedings,Boston Massachusetts,USA,1999.
  • 5Laine D L,Binley A M,Darilek G T.Locating geomembrane liner leaks under waste in a landfill[Z].Geosynthetics'97 Conference Proceedings,Long Beach California,USA,1997.

二级参考文献10

  • 1程乾生.数字信号处理的数学原理(第二版)[M].北京:石油工业出版社,1992..
  • 2SanjitK.Mitra数字信号处理--基于计算机的方法(第2版)[M].北京:清华大学出版社,2001..
  • 3贝兹JA 张志明等译.信号处理、调制与噪声[M].北京:人民邮电出版社,1985..
  • 4[2]Jordan Co. Performance standard for evaluating leak detection[ R]. USA:Environmental Protection Agency, 1984.
  • 5[3]Cregory P Van, Stephen K Park, Patrick Hamilton. Monitoring leaks from storage ponds using resistivity methods [ J ]. Geophysics, 1991,56 ( 8 ):1267- 1270.
  • 6[4]Andreas Rodel. Geologger: A new type of monitoring system for the total area--Geosynthetics: application, design and construction [ M ]. Rotterdam: Balkema, 1996. 625 - 626.
  • 7[5]Colucci P, Ecrozier, Laine D L. Geomembrane liner testing using the GLLS: a high-voltage electrical leak location system--Geosynthetics:application, design and construction [ M ]. Rotterdam: Balkema, 1996. 749- 750.
  • 8[6]Tohru Furuichi, Masaru Tanaka. Monitoring system for environmental risk management of a landfill disposal site [J]. Engineering Geology, 1993,(34) :169 - 174.
  • 9[7]Daren L Laine, Glenn T Darilek. Detecting leaks in geomembranes [ J ].Civil Engineering, 1993, (8): 50 - 59.
  • 10王斌,王琪,董路.垃圾填埋场防渗层渗漏检测方法的比较[J].环境科学研究,2002,15(5):47-48. 被引量:29

共引文献22

同被引文献91

引证文献8

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部