期刊文献+

基于不同频率成份衰减矫正的光声成像方法 被引量:15

Photoacoustic Imaging with Attenuation Rectification of Different Frequent Components of Photoacoustic Signal
在线阅读 下载PDF
导出
摘要 根据超声衰减理论,研究了光声信号不同频率成份随距离的衰减差异,及其对光声图像重建的影响;提出了对光声信号不同频率成份进行衰减矫正的成像方法,此方法增强了光声信号的高频成份,突出了吸收体的边界变化和细微的结构特征,提高了成像系统分辨率,实验结果显示系统分辨率由0.3mm提高到0.2mm.实验所用的光源为YAG激光器,波长为1064nm,重复频率为20Hz,脉宽为6ns,探测器为针状的PVDF膜水听器,接收面积的直径为1mm. The influences of attenuation coefficients of photoacoustic signals, which depends on frequencies, on the quality of reconstructed photoacoustic images has been explored. It reveals that the attenuation coefficients of low frequent components are less than those of high frequencies, and the latter are more important for photoacoustic imaging with high resolution. Based on the ultrasonic attenuation theory, the method of photoacoustic imaging with rectification of the attenuation of different frequent component was performed. The experiments results show that this method improves the resolution of reconstructed images, and the reconstructed images resolution improved from 0.3 mm to 0.2 mm. A Q-switched Nd : YAG laser operating at 1064 nm was used as light source. The laser had a pulse width of 6ns and a repetition frequency of 20 Hz. A needle PVDF hydrophone with diameter of 1 mm was used to detect photoacoustic signals.
出处 《光子学报》 EI CAS CSCD 北大核心 2005年第7期1019-1022,共4页 Acta Photonica Sinica
基金 国家重大基础研究前期专项(2002CCC00400) 国家自然科学基金面上项目(60378043) 广东省自然科学基金团队项目(015012)资助
关键词 光声成像 光声信号 衰减 矫正 Photoacoustic imaging Photoacoustic signal Attenuation Rectification
  • 相关文献

参考文献15

  • 1徐险峰,唐志列,汪洁,陈更生.光声信号的声透镜层析成像研究[J].光学学报,2003,23(9):1105-1109. 被引量:17
  • 2李忠明,骆清明.激光对生物组织热和热致机械损伤的物理分析[J].激光生物学报,2000,9(2):81-84. 被引量:8
  • 3邹文栋,司徒达,高益庆.固体中光声喇曼效应的原理特性分析[J].光子学报,2002,31(11):1373-1376. 被引量:3
  • 4Ku G, Wang L H. Scanning microwave-induced thermoacoustic tomography: signal, resolution, and contrast. Med Phys ,2001,28(1) :4~10.
  • 5Hoelen C G A, de Mul F F M, Pongers R, etal. Threedimensional photoacoustic imaging of blood vessels in tissue. Opt Lett, 1998,23(8): 648~650.
  • 6Oraevsky A A, Karabutov A A, Andreev V G, et al.Laser opto-acoustic imaging of the breast: detection of cancer angiogenesis. Proc SPIE, 1999,3597: 352~363.
  • 7Kruger R A, Liu P Y, Fang Y C, et al. Photoacoustic ultrasound ( PAUS)-Reconstruction tomography. Med Phys, 1995, 22(10):1605~1609.
  • 8Kruger R A, Reinecke D R, Kruger G A.Thermoacoustic computed tomography-technical considerations. Med Phys, 1999,26(9): 1832~ 1837.
  • 9Kostli K P, Frenz M, Bebie H, et al. Temporal backward projection of optoacoustic pressure transients using Fourier transform methods. Phys Med Biol,2001,46(7): 1863~ 1872.
  • 10Hoelen C G A, de Mul F F M. Image reconstruction for photoacoustic scanning of tissue structures. Appl Opt,2000,39(31): 5872~5883.

二级参考文献21

  • 1唐志列,司徒达,梁瑞生.液体的脉冲差分光声喇曼光谱[J].光学学报,1993,13(4):379-382. 被引量:5
  • 2刘方新,胡克良,王寅生,刘方平.纳米材料ZrO_2的傅里叶变换红外光声光谱研究[J].光学学报,1994,14(7):692-695. 被引量:5
  • 3Rosenewaig A.光声学和光谱学[M].Beijing: Science Press,1986.7-125(in Chinese).
  • 4Morse P M, Ingard K U. Theoretical Acoustics.Mcgraw-Hill, 1968.
  • 5Wade G. Acoustical Imaging Cameras, Microscopes,Phased Arrays and Holographic Systems. Pleum Press,1976.
  • 6Coufal H, Moller U, Schmeider S. Photoacoustic image using a Fourier transform technique. Appl. Opt , 1982,21(13) :2339-2343.
  • 7Frenz M, Kostli K P, Paltauf G et al . Reconstruction technique for optoacoustic imaging. Proc. SPIE, 2001,4256:130-137.
  • 8Magdalena C Pilatou, Roy G M, Kolkman Erwin Hondebrink a al.. Photoaeoustie imaging of blood perfusionin tissue and phantoms. Proc. SPIE, 2001, 4256:28-33.
  • 9Erel Granot, Aner Lev, Zvi Kotler et al.. Detection of inhomogeneities with ultrasound tagging of light. J.Opt. Soc. Am. (A), 2001, 18(8):1962-1967.
  • 10Paltauf G, Viator J A, Prahl S Aet al.. Iterative reconstruction method for three-dimensional optoacoustic imaging. Proc. SPIE, 2001, 4256:138-145.