摘要
文中用合成的偶氮氯磷-mA螯合形成纤维(以下称CPA-mA纤维)对地质样品中的稀土元素进行分离富集,并制成薄试样进行荧光X-射线光谱法测定[1,2]。CPA-mA纤维合成简单,交换速度快,在抗坏血酸和混合掩蔽剂(EDTA+CYDT+EGTA)存在下使痕量稀土元素及基体分离并得以富集。分析结果表明该方法的RSD小于15.68%,标准加入回收率在84.0~107.5%之间,能较好地满足地质工作的需要。
The method for separating and determining REEs in rocks has been presented.The seParation is characterized by better selection and higher exchangs speed with CPA-mA chelate-forming fibre. And the best background point(it is 26.48° with the crystal Li F220)Is used to subtract the background. The relative standard deviation is less than 15.68% and thedetectionlimlts are between 0.050(forPr6O11)-0.21μg/g(forTm2O3).
出处
《光谱学与光谱分析》
SCIE
EI
CAS
CSCD
北大核心
1995年第1期101-104,114,共5页
Spectroscopy and Spectral Analysis
关键词
稀土元素
分离富集
荧光
X射线光谱
岩石
REEs, Separation, X-ray fluorescence spectrometry, Chelate-forming fibre