摘要 穿戴式生物传感系统是近年发展起来的一种新型生命参数动态监测系统。该系统通常由无线的小型传感器、手持单元和专家系统构成。其中,穿戴式生物传感器和数据分析处理部分是生物传感系统中的两大技术。其研究发展分基础和应用两方面。在未来的发展中,穿戴式生物传感器将与多学科相结合并向小型化、智能化方向发展。 Wearable biosensors system(WBS system) is a newly developed monitoring device. It usually composes of wearable biosensors, a handheld PC,and an expert system. Wearable sensors and signal processing analysis procedures are two main techniques in WBS systems. The directions of research of WBS systems can be divided into basic research and its application. In the future, it will integrate into more subjects and become miniature and intelligentized.
出处 《国外医学(生物医学工程分册)》 CAS 2005年第3期138-142,共5页 Foreign Medical Sciences(Biomedical Engineering Fascicle)
关键词 穿戴式生物传感系统 穿戴式生物传感器 数字信号处理 闭环系统 临床监测 wearable biosensors system(WBS system) wearable biosensors (WBS) signal processing closes-loop system clinical monitoring
  • 相关文献

参考文献25

  • 1Gopalsamy C, Park S, Rajamanickam R, et al. The wearable motherboardTM: The first generation of ada ptive and responsive textile structures (ARTS) for medical applications [J]. Virtual Reality, 1999,4:152-168.
  • 2Bonato P. Wearable sensors systems and their impact on biomedical engineering[ J ]. IEEE Eng Med Biol Mag, 2003,22(3): 18-20.
  • 3Bonato P,Mork PJ,Sherrill DM,et al. Data mining of motor pattems recorded with wearable technology[ J ]. IEEE Eng Med Biol Mag, 2003,22(3): 110-119.
  • 4Asada HH, Shaltis P, Reisner A ,et al. Mobile monitoring with wearable photoplethysmographic biosensors [ J ]. IEEE Eng Med Biol Mag, 2003,22:28-40.
  • 5Katcher ML, Shapiro MM, Guist C. Severe injury and death associated with home infant cardiorespiratory monitors [J ]. Pediatrics, 1986,78(5): 775-779.
  • 6Kestin IG, Miller BR, Lockhart CH. Auditory alarms during anesthesia monitoring[J]. Anesthesiology, 1988,69(1):106-109.
  • 7Bentt LR, Santora TA, Leverle B J, et al. Accuracy and utility of pulse oximetry in the surgical intensive care unit[J]. Curr Surg, 1990,47(4):267-268.
  • 8Lanza GA, Lucente M, Rebuzzi AG, et al. Accuracy in clinical arrhythmia detection of a real-time holter system [ J ]. Electrocardiology, 1990,23(4): 301-306.
  • 9Cooper DH, Kennedy HL, Lyyski DS,et al. Holter triage ambulatory ECG analysis Accuracy and time effficiency[J]. Electrocardiology, 1996,29(1):33-38.
  • 10Zimetbaum PJ,Josephson ME. The evolving role of ambulatory arrhythmia monitoring in general clinical practice [J]. Ann Int Med, 1999,130(10):848-856.

同被引文献115