颅脑手术病人不同麻醉深度监测方法的比较 被引量:13

Comparison of three techniques monitoring depth of anesthesia during brain surgery
原文传递
导出
摘要 目的观察颅脑手术病人应用异丙酚镇静、芬太尼镇痛及异氟烷麻醉过程中脑电双频谱指数(BIS)、听觉诱发电位指数(AEPI)及电刺激-循环反应的变化及其在全麻深度监测中的价值。方法择期行颅脑手术病人20例,持续输注异丙酚0.25mg·kg-1·min-1,当异丙酚剂量达5mg/kg时停止输注。静脉注射芬太尼2μg/kg行气管插管,异氟烷维持麻醉。分别于异丙酚剂量达2.5、3.0、3.5、4.0、4.5、5.0mg/kg、静脉注射芬太尼后2min及呼气末异氟烷浓度稳定于0.7、1.0、1.3MAC时给予病人一次强直电刺激(ETS)。记录ETS前后BIS、AEPI及循环反应的变化[包括血压、心率(HR)变化幅度(△SP、△DP、△HR)及其恢复50%、90%的时间(TBP50%、TBP90%、THR50%、THR90%)]。结果BIS、AEPI与镇静程度呈正相关。ETS后BIS、AEPI变化不明显,但SP、DP、HR高于ETS前(P<0.01)。随异丙酚剂量和异氟烷浓度的增加,△SP和△HR逐渐变小,TBP50%、TBP90%、THR50%、THR90%逐渐缩短(P<0.01)。结论BIS、AEPI与镇静深度有较好的相关性,但不能反映镇痛;强直电刺激-循环反应的幅度可以反映镇痛,其中以△SP最直观。 Objective To evaluate the performance of bispectral index (BIS),auditory evoked potential index (AEPI) and cardiovascular response to electrical tetanus stimulus (ETS) for monitoring depth of sedation induced by propofol , analgesia produced by fenanyl and depth of isoflurane anesthesia. Methods Twenty ASA Ⅰ or Ⅱ patients of both sexes (11 males,9 females) aged 18-56 yr, weighing 50-80 kg undergoing elective brain surgery were studied. The patients were unpremedicated. The baseline BIS, AEPI, BP(SP, DP) and HR were measured before anesthesia. Propofol was infused at 0.25 mg·kg-1·min-1 and the infusion was stopped when the total amount of propofol infused reached 5 mg·kg-1 at the end of 20 min infusion. Fentanyl 2 μg·kg-1 was then given i.v. Three minutes later the patients were intubated and mechanically ventilated. Tracheal intubation was facilitated by vecuronium 0.1 mg·kg-1. Anesthesia was maintained with isoflurane. Depth of sedation was measured using OAA/S scale during propofol infusion. ETS was given at the following time points: when the amount of propofol infused reached 2.5, 3.0, 3.5, 4.0, 4.5, 5.0 mg·kg-1,2 min after fentanyl administration and at 0.7, 1.0, 1.3 MAC isoflurane (end-tidal isoflurane concentration). BIS and AEPI values before and after ETS and changes in BP and HR (ABP, AHR) after ETS and the time for BP and HR to return to the pre-ETS value in 50% and 90% of the patients (TBP50%,TBP90%,THR50%,THR90% ) were recorded. Results BIS and AEPI were positively correlated with sedation depth. There were no significant changes in BIS and AEPI after ETS, but SP, DP and HR increased significantly after ETS( P < 0.01). With increasing doses of propofol and increasing isoflurane concentration △BP and △HR induced by ETS became smaller and TBP50%,TBP90%,THR50%,THR90% shorter. Conclusion Both BIS and AEP correlate well with OAA/S scores and can be used to evaluate the depth of sedation and anesthesia brain surgery. The cardiovascular response to ETS(△BP and △HR) can indicate the intensity of pain and △SP is more sensitive.
出处 《中华麻醉学杂志》 CAS CSCD 北大核心 2005年第5期330-333,共4页 Chinese Journal of Anesthesiology
  • 相关文献

参考文献7

  • 1Struys MM, Jensen EW, Smith W, et al. Performance of the ARXderived auditory evoked potential index as an indicator of anesthetic depth: a comparison with bispectral index and hemodynamic measures during propofol administration. Anesthesiology, 2002, 96: 803-816.
  • 2Kurita T, Doi M, Katoh T, et al. Auditory evoked potential index predicts the depth of sedation and movement in response to skin incision during sevoflurane anesthesia. Anesthesiology, 2001, 95: 364-370.
  • 3Gajraj R J, Doi M, Mantzaridis H, et al. Analysis of the EEG bispectrum, auditory evoked potentials and the EEG power spectrum during repeated transitions from consciousness to unconsciousness. Br J Anaesth,1998, 80: 46-52.
  • 4Cajraj RJ, Doi M, Mantzaridis H, et al. Comparison of bispoctral EEG analysis and auditory evoked potentials for monitoring depth of anaesthesia during propofol anaesthesia. Br J Anaesth, 1999, 82: 672-678.
  • 5许海芳,董榕,任凤珍,沈永倩,于布为.双频指数和听觉诱发电位在监测麻醉深度中的价值[J].临床麻醉学杂志,2002,18(11):577-580. 被引量:24
  • 6Zbinden AM, Petersen Felix S, Thomson DA. Anesthetic depth defined using multiple noxious stimuli during isoflurane/oxygen anesthesia. Ⅱ.Hemodynamic responses. Anesthesiology, 1994, 80: 251-252.
  • 7徐华,王保国.不同浓度地氟烷对电刺激-循环反应的影响[J].麻醉与监护论坛,2002,9(2):13-15. 被引量:5

二级参考文献9

  • 1[1]Davies FW,Mantzaridis H,Kenny GN,et al .Middle latency auditory evoked potentia lsduring repeated transitions from cons ciousness to unconsciousness.Anaesthesia ,1996,51:107-113.
  • 2[2]Jensen EW,Nebot A,Caminal P,et al.Identification of causal relations between haemodynamic variables,auditory evoked potentials and isoflurane by means of fuzzy logic.Br J Anaesth,1999,82:25-32.
  • 3[3]Mantzaridis H,Kenny GNC.Auditory evoked potential index:aquantitative measure of changes in auditory evoked potential sduring general anesthesia.Anaesthesia, 1997,52:1030-1036.
  • 4[4]Chernik DA,Gillings D,Laine H,et al.Validity and reliability of the observers assessment of alertness/sedation scale:study with intravenous midazolam.J ClinPsycol Pharmacol,1990,10:224.
  • 5[5]Litvan H,Jensen EW,Maestre M,et al.Assessing depth of anaesthesia by auditory evoked potentials during continous propo fol infusion.Br J Anaesth,1999,82(Suppl 2):A20.
  • 6[6]Doi M,Gajraj RJ,Mantzaridis H,et al.Relationship between calculated blood concentraion of propofol and electrophysiological variables during emergence from an sethesia:comparison of bispectral index, spectral edge frequency,median frequency and auditory evoked potential index.Br J Anaesth,1997,78:180-184.
  • 7[7]Doi M,Gajraj RJ,Mantzatidis H,et al.Prediction of movement at laryngeal maska irway insertion:comparison of auditory evoked potential index,bispectral edge frequency and median frequency.Br J Anaest h,1999,82:203-207.
  • 8[8]Schwender D,Daunderer M,Mulzer S,et al .Midlatency auditory evoked potential predict movements during anesthesia with I soflurane or propofol.Anesth Analg,1997, 85:164-173.
  • 9[9]Urhonen E,Jensen EW,Lund J.Changes in rapidly extracted auditory evoked potentials during tracheal intubation.Acta Ana esthesiol Scand,2000,44:743-748.

共引文献27

同被引文献89

引证文献13

二级引证文献74

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部