DG-460/13.73-II3空气预热器着火原因分析及预防 被引量:3

Analysis of cause fired and its precaution of DG-460/13.73-Ⅱ3 air preheater
在线阅读 下载PDF
导出
摘要 以山东临沂华盛热电厂1号炉投煤吹管期间右侧空气预热器发生着火事故为例,分析了DG-460/13.73-II3型循环流化床锅炉空气预热器二次燃烧事故的原因,并提出相应的预防措施及事故发生时应采取的处理方式,强调运行人员要监测尾部烟道内各点温度和变化情况,保证锅炉安全经济运行。 Taking the reburn accident of right side air preheater of No.1 boiler in Shandong Linyi thermal power plant during the period of sand-blasting for instance, the causes for reburn accident of air preheater of DG-460/13.73-Ⅱ3 type CFB boiler were analyzed, the relevant precautions and the approaches to handling it when happened were also presented, emphasizing that operators should monitor the temperature variation situation of all points inside the tail flue and making the boiler operation safe and economy.
出处 《黑龙江电力》 CAS 2005年第3期238-240,共3页 Heilongjiang Electric Power
关键词 循环流化床锅炉 空气预热器 二次燃烧事故 CFB boiler air preheater reburn accident