摘要 目的 为了使4台血细胞分析仪检测结果一致且可以溯源到国际参考方法。方法 参照中华医学会检验分会血液分析仪校准规范化建议, 1台仪器用配套校准品校准后,定值1份新鲜血,再用这份新鲜血校准另外3台仪器。结果 3台仪器校准达到校准表要求。结论 仪器稳定性及重复性良好时,可用新鲜血校准多台仪器。 Objective To get same results from four hematology analyzers and trace the measure to the international reference standard. Methods According to the hematology analyzer calibration criterion suggested by Society of Medical Laboratory of Chinese Medical Association, one fresh blood sample was determined by one hematology analyzer calbirated with corresponding system calibrator, then the fresh blood was used to calibrate other four hematology analyzers. Results Three hematology analyzers matched with the calibration criterion. Conclusions When the hematology analyzers own good stability and precision, they can be calibrated by fresh blood.
出处 《检验医学》 CAS 北大核心 2005年第3期198-200,共3页 Laboratory Medicine
  • 相关文献

参考文献4

二级参考文献11

  • 1[1]International Committee for Standardization in Hematology;Expert p anel on cytometry.Reference method for the enumeration of erythrocytes and leuk ocytes[J]. Clin Lab Heamat,1994,16∶131-138.
  • 2[2]International Committee for Standardization in Hematology;Expert panel o n hemoglobinometry.Recommendations for reference method for hemoglobinometry in human blood(ICSH standard 1986)and specifications for international hemoglobincy anide reference preparation 3rd[J].Clin Lab Haematol,1987,9∶73-79.
  • 3[3]NCCLS.Precedure for Determining Packed Cell Volume by the Microhematioc r it Method-Second Edition;Approved Standard[S].NCCLS Document H7-A2, Vol.1 3 No 9,1993,13(9).
  • 4Allison F S. A historical review of quality control in hematology [J ].American Technology, 1983,49: 625-632.
  • 5Watanabe K, Kawai Y, Takeuchi K. Defferenee of blood cell counts with reference blood cell counters in different makers Part Ⅱ [ J ]. Rinsho Byori, 1997,45: 185-189.
  • 6Lewis SM.Harmonization and standardization of the blood countthe role of the ICSH cytometry panel-[].Sysmex J Int.1999
  • 7Bain,Barbara J.Detecting erroneous blood counts, chapter 4 (132146) of blood cells -a practical guide- 2nd Edition, Blackwell Science[].United Kingdom.1995
  • 8Cornbleet J.Spurious results from automated hematology cell counters[].Laboratory Medicine.1983
  • 9ICSH HGB Expert Panel.Recommendation for reference method for haemoglobinometry in human blood and specifications for international haemiglobincyanide standard[].Journal of Clinical Pathology.1996
  • 10ICSH Cytometry Panel.Platelet counting by the RBC/patelet Ratio Method-A reference Method-[].American Journal of Clinical Pathology.2001

共引文献114

同被引文献65

引证文献13

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部