期刊文献+

动态增强磁化率MR灌注成像在脑膜瘤分型中的价值 被引量:2

Subtyping of meningiomas with DSC MR perfusion imaging
暂未订购
导出
摘要 目的分析脑膜瘤的上皮型、纤维型、血管瘤型、间变型等4个常见亚型肿瘤实质和瘤周水肿区的血供,评价动态增强磁化率MR(dynamicsusceptibility-contrastMR,D)SC灌注成像技术表达不同亚型脑膜瘤灌注特点的可行性。方法对33例经病理证实的脑膜瘤患者行手术前DSCM灌R注成像扫描。测量肿瘤实质部分及瘤周水肿区最大相对脑血容积(relativecerebralbloodvolurmCeB,V)值及相应部位相对平均通过时间(relativemeantransittime,rM数TT值)并将结果进行分组统计分析。结果血管瘤型脑膜瘤实质部分的最大rCBV值高于其它亚型,有统计意义差异(方差分析,P<0.05);间变性脑膜瘤瘤周水肿区的最大rCBV值高于其它亚型,有统计意义差异(方差分析,P<0.05);各亚型间rMTT值无统计意义差异。结论DSCMR灌注成像对脑膜瘤的分型有临床价值。 Objective To evaluate the role of DSC MR perfusion imaging in pre-operation subtyping of meningiomas on the basis of differences in their vascularity inboth tumor parenchyma and peritumoral region. Subtypes of meningiomasinclude endothelium, fibroid and angioblastic. Methods 33 patients with meningiomasunderwent DSC MR perfusion imaging before resection. Maximum relative cerebralblood volume (rCBV) and corresponding relative mean transit time (rMTT) values ofthe same part in both parenchyma of meningiomas and peritumoral region were calculated.Data were analyzed group by group. Results Maximum rCBV in parenchyma ofangioblastic subtype was significantly higher than that of other subtypes (ANOVEanalysis, P < 0.05); maximum rCBV of anaplastic subtype in the peritumoral regionswas significantly higher than of other subtypes (ANOVE analysis, P < 0.05). rMTTvalues of all subtypes were not significantly different. Conclusion DSC MR perfusionimaging is clinically useful in subtyping of meningiomas.[
出处 《中国CT和MRI杂志》 2005年第3期3-5,共3页 Chinese Journal of CT and MRI
关键词 脑膜瘤 磁共振成像 脑血流灌注 动态增强磁化率HR灌注成像 肿瘤分型 影像学 meningioma magnetic resonance imaging (MRI) perfusion brain blood flow
  • 相关文献

参考文献4

二级参考文献65

  • 1[1]Reuben M. A perspective on Kspace. Radiology, 1995,195(2):297-315
  • 2[2]Pruessmann KP, Weiger M,Scheidegger MB, at al. SENSE:Sensitivity Encoding for Fast MRI.Magn Reson Med,1999,42(5):952-962.
  • 3[3]Brink J, Watanabe Y, Kuhl CK,et al. Implication of SENSE MR in routine clinical practice. E JR, 2003,46(1):3-27.
  • 4[4]Weiger M, Pruessmann KP,Boesiger P. Cardiac Real-Time Imaging Using SENSE. Magn Reson Med,2000,43(2): 177-184.
  • 5[5]Weiger M, Pruessmann KP,Leussler C, et al. Coil design for SENSE: a six-element cardiac array. Magn Reson Med, 2001,45(3):495-504.
  • 6[6]Weiger M, Pruessmann KP, Kassner A, et al. Contrast-enhanced 3D MRA using SENSE. J Magn Reson Imaging, 2000,12(5): 671-677.
  • 7[7]Golay X, Pruessmann KP, Weiger M, et al. PRESTO-SENSE: an ultrafast whole-brain fMRI technique. Magn Reson Med,2000,43(6):779-786.
  • 8[8]Dydak U, Weiger M, Pruessmann KP, et al. Sensitivity-encoded spectroscopic imaging. Magn Reson Med,2001,46(4):713-722.
  • 9[9]Bammer R, Keeling SL, Augustin M, et al. Improved diffusionweighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE). Magn Reson Med, 2001,46(3): 548-554.
  • 10[1]Zülch KJ. Histologic typing of tumours of the central nervours system. Geneva, Switzerland: World Health Organization, 1979