期刊文献+

薄层扫描法同时测定七种镇静催眠药物的血药浓度 被引量:8

The qualitative and quantitative analysis of seven sedative hypnotics in pisoning and clinical application
暂未订购
导出
摘要 本文用CS-9000薄层扫描仪同时测定了硝西泮、氯硝西泮、安定、艾司唑仑、安眠酮、氯氮、三唑仑等7种镇静催眠药物的血药浓度,以正庚烷:氯仿:无水乙醇:乙酸乙酯(5:2:2:1.5)为展开剂,Rf值分别为0.68.0.63,0.59,0.34,0.71,0.49,0.28,测定波长分别为260nm,240nm,31Onm,238nm,305nm,264nm,230nm,线性范围1~10μg/ml,相关系数0.9972~0.9999,回收率:92.86%~100.6%,板内板间误差CV%0.28%~4.92%。 edative-hypnotics are used extensively in clinical therapy.Sometimes people took an over dosage or committed suicide bytakinging these drugs. Doctors did not know which kind of these drugs causing poising.In order to give an early diagnosis foreffective rescue,we have established a rapid,accurate and reliable TLC methed. Seven sedative hypnotics could be determinedsimultaneously using one developing system. The clinical application was satisfactory.
出处 《中国医院药学杂志》 CAS CSCD 北大核心 1994年第1期3-5,共3页 Chinese Journal of Hospital Pharmacy
关键词 镇静药 催眠药 薄层扫描 血药浓毒 sedative-hypnotic,drugs poisoning,TLC