期刊文献+

用激光吹气注入高Z杂质使HL-1M托卡马克放电安全终止的研究 被引量:2

Potential safe termination by laser ablation of high-Z impurity in the HL-1M tokamak
原文传递
导出
摘要 采用高Z杂质注入HL1M等离子体中,触发等离子体电流衰竭的实验已经施行.用激光吹气注入高Z杂质能够增加辐射冷却,等离子体在-3ms时间内迅速冷却而且在电流终止之前电子温度损失约80%.实验证明它是一种使得大型聚变实验装置上在放电破裂之前显著减少等离子体中热能而且安全终止放电的简单、快速和有效的途径. A preliminary experiment for triggering a Plasma current quench by means of injection of high-Z impurities has been performed on the HL-1M before the major disruption. Using injection of impurity with higher charge of the nuclei allows us to increase the radiation cooling on a 3 ms time scale and the electronic temperature loss contract is 80% before current terminates. It can be a simple and potential approach to decrease significantly the plasma thermal energy and the magnetic field energy before a disruption and to a safe plasma termination.
出处 《物理学报》 SCIE EI CAS CSCD 北大核心 2005年第6期2809-2813,共5页 Acta Physica Sinica
关键词 高Z杂质 HL-1M托卡马克 等离子体 激光吹气 电流衰竭 high-Z impurities disruption safe plasma termination laser ablation
  • 相关文献

参考文献6

  • 1Wesson J A et al 1991 Nucl.Fusion 31 641.
  • 2Yamazaki K and Schmidi G L 1999 Nucl. Fusion 39 845.
  • 3Kuteev B V, Sergeev V Yu and Sudothe S 1995 Nucl.Fusion 35 397.
  • 4骆翠贤.核聚变与等离子体物理,1997,15(4):37-37.
  • 5郑永真,齐昌炜,丁玄同,郦文忠.HL-1M装置逃逸电子输运系数的研究[J].核聚变与等离子体物理,2002,22(2):90-94. 被引量:3
  • 6Jayakumar R 1993 Phys.Lett.A 172 447.

二级参考文献1

  • 1郑永真.HL-1M装置中微波辐射和硬X射线辐射损失通量锯齿之间的关系[M].成都:核工业西物理研究院,2000..