摘要
分析了影响垃圾填埋场渗滤液产生量多少的因素,比较了渗滤液产量的计算方法,并通过工程实例计算了渗滤液产量及调节池容积,在调节池设计上采用了浮盖技术,以满足渗滤液预处理功能和控制蚊蝇滋生及臭气外逸,目的是便于有关人员在使用《生活垃圾卫生填埋技术规范》(CJJ172004)标准时能正确理解调节池设计规定。
The purpose of this paper is that relevant personnel could understand the prescribe of designing equalization when they use Technical Code for Municipal Solid Waste Sanitary Landfill(CJJ17-2004). The paper analyzed the factors affecting leachate generation for landfill and compared the methods of calculating leachate generation. Simultaneously, it took the sanitary landfill project for example, calculated leachate generation and cubage of leachate equalization basin, and designed the floating cover to meet the need of leachate pretreatment so as to control mosquito, fly and effluvium.
出处
《安全与环境工程》
CAS
2005年第2期38-40,共3页
Safety and Environmental Engineering
基金
建设部<生活垃圾卫生填埋技术规范>(CJJ172004)资助项目。
关键词
垃圾填埋场
渗滤液
调节池
浮盖
sanitary landfill
leachate
equalization basin
floating cover