期刊文献+

神经导航显微手术切除颅内肿瘤 被引量:6

Neuronavigator-guided microsurgery for the resection of intracranial tumors
原文传递
导出
摘要 目的探讨应用神经导航辅助显微外科手术切除颅内肿瘤的作用方法采用VectorVision神经导航系统、以显微外科技术切除215例颅内肿瘤,分析导航定位的准确性及与疗效的关系结果215例颅内肿瘤,全切除209例(97.2%)、次全切除6例(2.8%)。出院时患者症状明显改善186例(86.5%)、无明显变化27例(12.6%),死亡2例(0.9%)应用VectorVision的注册准确性为(1.95±0.54)mm,持续准确性为(0.65±0.32)mm。结论使用VectorVision神经导航系统,在术前可制定详细的颅内肿瘤手术计划,术中可辅助显微手术动态地追踪瘤体,手术定位准确、可靠,有利于颅内肿瘤的全切除并降低手术并发症。 Objective To evaluate the effectiveness of neuronavigator-guided microsurgical surgery for the resection of intracranial tumors. Methods A total of 215 patients with intracranial tumors underwent microsurgical treatment under the Vector Vision neuronavigator to estimate the extent of the tumors. The treatment effects were summanzed and the neuronavigational accuracy was discussed. Results In 215 patients, total tumor removal was achieved in 209 cases (97.2%) , subtotal removal in 6 cases (2.8%). The neurological (functions were improved obviously in 186 patients (86.5%) ,unchanged in 27 (12.6%) ,and death was in 2 (0.9%). For Vector Vision,mean fiducial error (MFE) and sustained accuracy (SA) were (1.95±0.54) mm and (0.65±0.32) mm repectively. Condusion They are reliable and accurate in making microneurosurgical plans for intraeranial tumors by using Vector Vision navigation systems. And it can provide dvnamic tracing of the tumor in the microsurgical operation and guide the manipulation. This teehnique helps total removal of the intracranial tumors and a decrease in surgical complications.
出处 《中华显微外科杂志》 CSCD 北大核心 2005年第2期116-118,共3页 Chinese Journal of Microsurgery
基金 国家自然科学基金资助项目(30370512)第四军医大学西京医院临床新技术基金(XJGX03015M07)
  • 相关文献

参考文献4

二级参考文献12

  • 1朱涛,杨树源,孙银水.88例肢端肥大症的经蝶手术观察[J].中华神经外科杂志,1995,11(5):264-266. 被引量:5
  • 2Roberts DW,Strohbehn JW,Hatch JF,et al. A frameless stereoraxic integration of computerized tomographic imaging and the operating microscope. J Neurosurg,1986,65:545-548.
  • 3Watanabe E, Watanabe T, Manaka S,et al. Three-dimentional digitizer ( neuro-navigator ) , A new equipment for CT-guided stereotaxic surgery. Surg Neurol, 1987,27:543-547.
  • 4Ziarecuich SJ , Tebo SA, Long DM, et al. Framelcss stereotaxic integratioa of CT imaging data, Accuracy and initial appticaliorts. Radiology, 1993, 188:735-745.
  • 5Golfinos JG, Fitzpatrick BC, Smith LR, et al. Clinical use of a frameless stereotactie arm: results of 325 cases.J Netlrosurg, 1995, 83:197-205.
  • 6Patel N , Saademan DR , Colly M , et al. Interative imageguided surgery of the spine use of the ISG/ELekta Viewing Wand to aid intraopcratine Localization of a sacral osteoblastomea, BJ Neurosurg, 1997, 11: 60-64.
  • 7Sipoa EP, Tebo SA , Zinreich SJ, et al, In vivo accuracy testing and clinical experience with the ISG Viewing Wand. Nemosurgcry, 1996,39:194-204.
  • 8Tan KK, Graeszczuk R. Levin DN, et al. A frameless stereotactic approach to neurosurgical planning based on retroapective patient-image registration. J Neurosurg,1993,79:296-303.
  • 9Ryan MJ,Eroksoa RK , Lerin DN ,et al, Frameless sterotaxy with real-time tracking of patient head movement and retrospactive patient-image registration. J Neurosurg.1996,85:287-292.
  • 10Vrionis FD, Foley KT, Rohertson JH, et al. Use of cranial surface anatomic fidudals for interative imageguided navigation in the temporal bone: a cadavcric study, Neurosurgery, 1997, 40:755-764.