摘要
电力系统机组组合问题是一个典型的大规模混合整数的非线性组合优化问题,很难得到理论上的最优解。该文提出了求解机组组合问题的多智能体体系结构,并且提出了自治与分级管理相结合的3层MAS系统体系结构,最终通过协调Agent、任务Agent、发电Agent的协商、谈判,获得了机组组合问题的一个较为满意的解。
Power system unit commitment, a problem of nonlinear commitment optimization with typical large-scale hybrid integers, is difficult to get an optimal solution in theory. To solve this problem, this paper proposes a multi-agent system, and the structure of three-layer MAS combined with autonomy and level-management is provided. With the consulation and negotiation between coordinate Agent, task Agent and power-generating Agent, an optimal solution for unit commitment problems is obtained. The experiment results prove that the multi-agent system is able to find a satisfactory optimal solutions.
出处
《继电器》
CSCD
北大核心
2005年第8期22-26,共5页
Relay