超声心动图和左室造影测量膜部室间隔缺损的相关研究

comparative study on the measurement of ventricular septal defect by ultrasoundcardiogram and by left ventriculography
暂未订购
导出
摘要 目的对比分析超声心动图(UCG)和左室造影(LV)定量测量膜(周)部室间隔缺损(VSD)的相关性。方法全组患者106(男49,女57)例,年龄2~45(9.6±8.3)岁。UCG采用非标准左室长轴、大血管短轴及五腔切面;LV取左前斜位45°~60°加头位25°,测量VSD的大小,与主动脉瓣右冠瓣的距离。结果LV测量VSD大小显著大于左室长轴超声测量值(7.4±2.9mmvs5.2±2.3mm,P<0.05),而与大血管短轴及五腔心切面UCG测量值(7.0±2.9mm,7.0±3.2mm)无显著性差异(P>0.05)。大血管短轴与五腔心切面UCG测量VSD大小值之间无显著性差异(P>0.05),但显著大于左室长轴切面测值(P<0.05)。LV测量VSD距主动脉瓣距离显著大于左室长轴切面测值(3.4±1.0mmvs2.3±0.7mm,P<0.05),而与五腔心切面测值(3.0±1.0mm)无显著性差异(P>0.05)。五腔心切面所测室间隔缺损距主动脉瓣距离亦与LV测值显著相关(r=0.84,P<0.01)。UCG在大血管短轴切面所测室缺与三尖瓣的距离为3.3±1.3(1.5~7)mm。结论膜部VSD介入治疗时仍应以LV测量VSD的大小和位置为选择封堵器的“金标准”,UCG测量可以作为左室造影的重要补充;而VSD与三尖瓣的距离只能用UCG测量。 AIM: To compare the measurement of ventricular septal defect (VSD) by ultrasoundcardiogram (UCG) and by left ventriculography (LV). METHODS: Total 106 VSD patients (49 male, 57 female), aged from 2 to 45 (average, 9.6±8.3), were investigated. By UCG, the size of VSD and the distance between VSD and the right coronary cusp was measured at non-standard parasternal left heart long axis view, parasternal aortic short axis view and apical 5-chamber view. By LV, the size of VSD and the distance between VSD and right coronary cusp were measured in left anterior oblique 45° ~60° +cranial 25°LV. RESULTS: The size of VSD measured in LV was significantly larger than that measured by parasternal left heart long axis view UCG (7.4±2.9 mm vs 5.2±2.3 mm, P<0.05), but no significant difference with that measured by parasternal aortic short axis view and apical 5-chamber view UCG (7.0±2.9 mm vs 7.0±3.2 mm, P>0.05). The size of VSD measured by parasternal aortic short axis view UCG had no significant difference with that measured at apical 5-chamber view UCG (P>0.05),but was significantly larger than that measured at parasternal left heart long axis view UCG (P<0.05).The distance of VSD to aortic valve measured by LV was significantly larger than that measured by parasternal left heart long axis view UCG (3.4±1.0 mm vs 2.3±0.7 mm, P<0.05),but no significant difference with that measured by apical 5-chamber view UCG (3.4±1.0 mm vs 3.0±1.0 mm, P> 0.05 ). The distance between VSD and aortic valve measured by apical 5-charmer view UCG was also significantly correlated with that measured by LV (r=0.84, P<0.01). The distance betweem VSD and tricuspid valve measured by parasternal aortic short axis view UCG was from 1.5 to 7 mm (averaged, 3.3±1.3mm). CONCLUSION: The size and location of VSD measured by LV should be 'golden standard' in selecting the occluders in transcatheter occlusion of VSD. UCG can be an important complementary to LV. The distance of VSD to tricuspid valve can only be measured by UCG.
出处 《心脏杂志》 CAS 2005年第2期192-194,共3页 Chinese Heart Journal
关键词 室间隔缺损 超声心动描记术 心室造影 ventricular septal defect ultrasoundcardiogram ventriculography
  • 相关文献

参考文献2

二级参考文献10

  • 1[1]Fisher G,Kramer HH,Stieh J,et al.Transcatheter closure of secundum atrial septal defects with new self-centering Amplatzer Septal Occluder[J].Eur Heart J,1999,20(7):541-549.
  • 2[2]Berger F,Ewert P,Abdul-khaliq H,et al.Percutaneous closure of large atrial septal defects with the Amplatzer septal occluder: Technical overkill or recommendable treatment?[J].J Interven Cardiol,2001,14(1):63-67.
  • 3[3]King TD,Thompson SL,Mills NL.Measurement of atrial septal defect during cardiac catherization.Experimental and clinical results[J].Am J Cardiol,1978,41:537-542.
  • 4[4]Rao PS,Langhough R.Relationship of echocardiographic,shunt flow and angiographic size of the stretched diameter of atrial septal defect[J].Am Heart J,1991,122:505-508.
  • 5[5]Godart F,Rey C,Francart C,et al.Two-dimensional echocardiographic and color Doppler measurements of atrial septal defect,and comparison with the balloon-stretched diameter[J].Am J Cardiol,1993,72:1095-1097.
  • 6[6]Hijazi ZM,Cao Q,Patel HT,et al.Transesophageal echocardiogrophic results of catheter closure of atrial septal defect in children and adults using the Amplatzer device[J].Am J Cardiol,2000,85:1387-1390.
  • 7[7]Minich LL,Snider AR.Echocardiographic guidance during placement of the buttoned-disk device for atrial septal defect closure[J].Echocardiography,1993,10(6):567-572.
  • 8[8]Chan KC,Godman MJ.Morphological variation of fossa ovalis atrial septal defects (secundum):feasibility for transcutaneous closure with the clam-shell device[J].Br Heart J,1993,69:52-55.
  • 9秦永文,胡建强,赵仙先,毛红娟.应用国产双盘状封堵器治疗房间隔缺损三例报告[J].第二军医大学学报,2000,21(5):496-496. 被引量:8
  • 10秦永文,胡建强,赵仙先.自制镍钛合金室间隔缺损封堵器的生物相容性研究[J].第二军医大学学报,2001,22(11):1038-1040. 被引量:7

共引文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部