期刊文献+

Detection of ultrasound contrast agent microbubble with constructed bubble wavelet 被引量:7

Detection of ultrasound contrast agent microbubble with constructed bubble wavelet
原文传递
导出
摘要 To detect the echo irradiated by microbubble out from the signal reflected by surrounding tissues, a mother wavelet named bubble wavelet according to the modified Herring oscillation equation was constructed and then applied to the original ultrasound radio frequency signal to perform the wavelet transformation. The transformed wavelet coefficients were extracted by selected threshold values to differentiate the echo of microbubble from signal of surround tissues. The effect of bubble wavelet was compared with other three commonly used mother wavelets by computer simulation and phantom experiment. The results demonstrated that there existed a highly correlation between the bubble wavelet and the experimental echo irradiated by microbubble because bubble wavelet had represented the dynamics of microbubble in advance. Furthermore, the wavelet transform results showed a better signal-noise-ratio and a sharper contrast between the echo of microbubble and the signal of surrounding tissues. Finally, constructing an overall mother wavelet library can improve the applicability and robustness of this detection method. To detect the echo irradiated by microbubble out from the signal reflected by surrounding tissues, a mother wavelet named bubble wavelet according to the modified Herring oscillation equation was constructed and then applied to the original ultrasound radio frequency signal to perform the wavelet transformation. The transformed wavelet coefficients were extracted by selected threshold values to differentiate the echo of microbubble from signal of surround tissues. The effect of bubble wavelet was compared with other three commonly used mother wavelets by computer simulation and phantom experiment. The results demonstrated that there existed a highly correlation between the bubble wavelet and the experimental echo irradiated by microbubble because bubble wavelet had represented the dynamics of microbubble in advance. Furthermore, the wavelet transform results showed a better signal-noise-ratio and a sharper contrast between the echo of microbubble and the signal of surrounding tissues. Finally, constructing an overall mother wavelet library can improve the applicability and robustness of this detection method.
出处 《Chinese Journal of Acoustics》 2005年第2期131-145,共15页 声学学报(英文版)
基金 ThiswassupportedbytheNationalNaturalScienceFoundationofChina(30270404).
  • 相关文献

参考文献2

二级参考文献10

共引文献44

同被引文献44

引证文献7

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部