1[1]Molyneux A, Kerr R, Stratton I, et al. International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2 143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet, 2002, 360:1267-1274.
2[2]Henkes H, Drepper P, Speder J, et al. Technical note on VDS: a system for the endovascular electrolytical. Interv Neuroradiol, 2002, 8:197-200.
3[3]Thammaroj J, Jayakrishnan V, Lamin S, et al. MTI (Dendron) variable detachable coils: preliminary clinical experience in cerebral aneurysms in Glasgow. Interv Neuroradiol, 2003, 9:47-52.
4[4]Pierot L, Flandroy P, Turjman F, et al. Selective endovascular treatment of intracranial aneurysms using micrus microcoils: preliminary results in a series of 78 patients. J Neuroradiol, 2002, 29:114-121.
5[5]Leonardi M, Simonetti L, Cenni P, et al. 3D Micrus coil "cage" in wide-necked aneurysms. Interv Neuroradiol, 2003, 9:141-152.
6[6]Piotin M, Iijima A, Wada H, et al. Increasing the packing of small aneurysms with complex-shaped coils: an in vitro study. AJNR Am J Neuroradiol, 2003, 24:1446-1448.
7[7]Murphy KJ, Mandai S, Gailloud P, et al. Neurovascular embolization:in vitro evaluation of a mechanical detachable platinum coil system.Radiology, 2000, 217:904-906.
8[8]Murphy KJ, Houdart E, Szopinski KT, et al. Mechanical detachable platinum coil: report of the European phase Ⅱ clinical trial in 60patients. Radiology, 2001, 219:541-544.
9[9]Sugiu K, Katsumata A, Kusaka N, et al. Usefulness of a new mechanical detachable coil for neurovascular intervention. No Shinkei Geka, 2001, 29:933-940.
10[10]Piotin M, Mandai S, Murphy KJ, et al. Dense packing of cerebral aneurysms: an in vitro study with detachable platinum coils. AJNR Am J Neuroradiol, 2000, 21:757-760.
6[2]Zenteno M.Santos-Franco J,Aburto-Murrieta Y,et al.Superior cerebellar artery aneurysms treated using the sole stenting approach:technical note.J Neurosurg,2007,107:860-864.
7[3]Shin YS,Kim HS,Kim SY.Stenting for vertebrobasilar dissection:a possible treatment option for nonhemorrhagic vertebrobasilar dissection.Neuroradiology,2007,49:149-156.
8[4]Greenberg E,Katz JM,Janardhan V,et al.Treatment of a siant vertebrobasilar artery.aneurysm using stent grafts:case report.J Neumsurg,2007,107:165-168.
9[5]Zenteno M,Medenesi Freitas JM,Aburto-Murrieta Y,et al.Balloon-expandable stenting with and without coiling for wide-neckand complex aneurysms.Surg Neurol,2006,66:603-610.
10[6]Benndorf G.Herbon U,S,llmann WP,et al.Treatment of a ruptured dissecting vertebral artery aneun,sm with double stent placement:ease report.AJfNR Am J Neuroradiol,2001,22:1844-1848.