变压器漏油和起火是油浸变压器在运行过程中的常见问题, 为此, 针对变压器结构设计不合理、制造工艺水平不高、材质选用不当及现场安装操作不规范等几方面因素提出相应的处理方法及预防措施, 以解决变压器渗漏油及防火问题, 保证电网的安全稳定运行。
To solve the common problems of oil leakage and fire hazard in oil-immersed transformers during operation,this paper puts forward corresponding treating and precautionary measures in view of failure-causing factors such as irrationally designed transformer structure,poorish manufacture procedures,improper material and nonstandard on-site installation and operation,thus ensuring the safety and reliability of power grid.