期刊文献+

UASB+AF处理维生素C废水的研究 被引量:17

Study on the Treatment of wastewater from the Production Process of Vitamin C by Using a Complex Reactor of Upflow Anaerobic Sludge Blanket-Filter
在线阅读 下载PDF
导出
摘要 采用有效容积为6m3的UASB+AF反应器处理维生素C高浓度有机废水,结果表明:稳定运行容积负荷可达10—12kgCOD/(m3·d)COD去除率大于80%,容积产气率大于3.0Nm3/(m3·d),并具有启动速度快和较强耐冲击负荷的能力。 A complex reactor of upflow anaerobic sludge blanket-filter (UASB+AF) with an available volume of 6m3 was used to treat a highly concentrated organic wastewater from the production process of Vitamin C. During the Period of its stable operation,it had a volumetric COD loading of up to 10-12kg COD/ (m3.d ), a COD removal of over 80%, and a volumetric biogas yield of over 3.0 Nm3/(m3.d),as well as a high start-up speed and a stronger resistance to shock loading.
出处 《环境科学》 CAS CSSCI CSCD 北大核心 1994年第6期54-57,共4页 Environmental Science
基金 国家"七五"科技攻关项目
关键词 维生素C废水 纤维填料 UASB+AF 废水处理 up flow anaerobic sludge blanket-filter reactor, wastewater, Vitamin C, synthetic fiber filter