低频噪声干扰的评价标准和控制技术 被引量:3

INFLUENCE OF LOW FREQUENCY NOISE AND ITS CONTROL
原文传递
导出
摘要 本文对16—31.5Hz范围的低频噪声对居民的干扰作了调查,对噪声源进行了测试和分析。在控制前,对措施作了分析;在施工过程中,逐项进行了检验。在峻工后作了全面测试。结果表明,在按影响严重性区分的居民区Ⅰ、Ⅱ和Ⅲ中,25Hz峰值声压级分别从原有的95dB降至74dB,91dB降至66dB,83dB降至65dB,达到满意的效果。 我们结合措施设计,对低频隔声作了理论估算并与实验作了比较,证明在劲度控制区利用有效劲度,理论和实验符合很好。还从对居民的调查中,提出一个低频声干扰的初步建议。 The influence of low frequency noise within 16 to 31.5 Hz has been surveyed and measured. The properties of the noise source are analysed before the control and in the course of the control. Final test shows that the SPL in the resident area I, II and III classified according to the seriousness of the interference may be reduced from 95 dB to 74 dB, 91 dB to 66 dB, and 83 dB to 65 dB respectively. We calculated the low frequency sound transmission loss of wall and compared them with the experiments. If the effective stiffness we proposed is used the experiments are well in accordance with the calculation. In addition, we propose some criteria for low frequency noise interference according to our survey results.
出处 《声学学报》 EI CSCD 北大核心 1989年第4期270-278,共9页 Acta Acustica
  • 相关文献

参考文献2

  • 1吕如榆,振动和噪声控制,1985年,5卷,43页
  • 2团体著者,振动与声,1974年

同被引文献28

  • 1姜建国,张昕,曹诗玉.龙泉换流站噪声源及综合治理[J].湖北电力,2010,34(5):26-27. 被引量:4
  • 2杨一鸣,章旭雯.特高压直流换流站设备的降噪措施[J].高电压技术,2006,32(9):149-152. 被引量:54
  • 3余尤好,陈宝志.大型电力变压器的噪声分析与控制[J].变压器,2007,44(6):23-26. 被引量:53
  • 4潘仲麟,金进生,黄有兴,斯公寿.测听室声学特性的设计研究[J]应用声学,1988(03).
  • 5杨新村;沈江;傅正财.输变电设施的电场、磁场及其环境影响[M]北京:中国电力出版社,200710-12187-188.
  • 6刘振亚.特高压电网[M]北京:中国经济出版社,2005.
  • 7梁冬.输变电工程节能环保设计研究[R]北京:国网北京经济技术研究院,2010.
  • 8黄莹;黄成;李志远.±800 kV云广直流输电工程楚雄、穗东换流站噪声综合治理方案[R]广州:南方电网科学研究院,2011.
  • 9张新宁;杜祥庭;陈新龙.SoundPLAN软件在特高压交流变电站噪声预测中的应用探讨[A]成都:四川省环境科学学会,200915-27.
  • 10丁扬;王绍武;邱宁.320 MVar/1 100 kV并联电抗器噪声污染控制技术与装备的开发应用[A]北京:国家电网公司,20091-4.