期刊文献+

大剂量静脉尿路造影在泌尿系梗阻检查中的应用探讨 被引量:2

Evaluation of Large Amount of Contrast Excretory Urography in the Examination of Urinary Tract Obstruction
暂未订购
导出
摘要 目的 探讨大剂量静脉尿路造影在泌尿系梗阻检查中的应用价值。方法 对 5 0例采用常规剂量和双倍剂量静脉尿路造影检查显影欠佳的泌尿系梗阻患者 ,行大剂量静脉尿路造影检查进行比较。结果  5 0例泌尿系梗阻患者中 ,46例清楚显示狭窄和梗阻的位置及梗阻以上扩张的肾盂肾盏及输尿管 ,4例 3h后肾盂肾盏显影浅淡。结论 大剂量静脉尿路造影能提高造影的质量及泌尿系梗阻诊断的准确率。 Purpose To evaluate the value of large amount of contrast excretory urography in the examination of urinary tract obstruction. Methods The urography were performed with intravenous injection of large amount of contrast media in 50 patients with urinary tract obstruction, in whom the collecting system was showed unclearly with the routine or double dosage urography method. Results Among the 50 cases of urinary tract obstruction, 46 cases of which were clearly demonstrated the narrow or obstructive location and the dilation of the tract, the pelvis and calyces were showed faintly after 3 hours in 4 cases. Conclusion Large amount of contrast excretory urography could improve the quality of urography and the diagnostic accuracy of the urinary tract obstruction. [
出处 《中国医学影像技术》 CSCD 2003年第6期733-734,共2页 Chinese Journal of Medical Imaging Technology
关键词 泌尿系梗阻 静脉尿路造影 大剂量 肾盏 检查 肾盂 患者 扩张 目的 质量 Urinary Radiography Intravenous urography
  • 相关文献

参考文献3

  • 1于茂生.实用泌尿外科学[M].北京:中国人民解放军战士出版社,1980.98,101.
  • 2徐丽潮,王尔祯.白肾28例临床X线分析[J].临床放射学杂志,1996,15(5):294-296. 被引量:18
  • 3张镜如 乔健天.生理学[M].北京: 人民卫生出版社,1994.161-171.

二级参考文献1

共引文献22

同被引文献21

  • 1吴宇欣,崔静坤,张秀云.碘海醇引发肾结石1例报告[J].吉林大学学报(医学版),2006,32(6):1047-1047. 被引量:5
  • 2Johnson TR,Krauss B,Sedlmair M,et al.Material differentiation by dual energy CT:initial experience.Eur Radiol,2007,17(6):1510-1517.
  • 3Scheffel H,Stolzmann P,Frauenfelde TR,et al.Dual-energy contrast-enhanced computed tomography for the detection of urinary stone disease.Invest Radiol,2007,42(12):823-829.
  • 4Primak AN,Fletcher JG,Vrtiska TJ,et al.Noninvasive differentiation of uric acid versus non-uric acid kidney stones using dual-energy CT.Acad Radiol,2007,14(12):1441-1447.
  • 5Takahashi N,Hartman1 RP,Vrtiska1 TJ,et al.Dual-energy CT iodine-subtraction virtual unenhanced technique to detect urinary stones in an iodine-filled collecting system:a phantom study.AJR Am J Roentgenol,2008,190(5):1169-1173.
  • 6Graser A,Johnson TR,Chandarana H,et al.Dual energy CT:preliminary observations and potential clinical applications in the abdomen.Eur Radiol,2009,19(1):13-23.
  • 7Petersilka M,Bruder H,Krauss B,et al.Technical principles of dual source CT.Eur J Radiol,2008,68(3):362-368.
  • 8Flohr TG,McCollough CH,Bruder H,et al.First performance evaluation of a dual-source CT (DSCT) system.Eur Radiol,2006,16(2):256-268.
  • 9Johnson TR,Nikolaou K,Wintersperger BJ,et al.Dual source CT cardiac imaging:initial experience.Eur Radiol,2006,16(7):1409-1415.
  • 10Deetjen A,Mollmann S,Conradi G,et al.Use of automatic exposure control in multislice computed tomography of the coronaries:comparison of 16-slice and 64-slice scanner data with conventional coronary angiography.Heart,2007,93(9):1040-1043.

引证文献2

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部